Eaton Powerware 9130 User Manual

Manual is about: 700–3000 VA UPS

Summary of Powerware 9130

  • Page 1

    Eaton 9130 ups 700–3000 va user's guide ®.

  • Page 2: Class A Emc Statements

    Class a emc statements (low voltage models over 1500 va) fcc part 15 note this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference whe...

  • Page 3: Class B Emc Statements

    Class b emc statements (low voltage models up to 1500 va and high voltage models up to 3000 va) fcc part 15 note this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable prot...

  • Page 4: Special Symbols

    Requesting a declaration of conformity units that are labeled with a ce mark comply with the following harmonized standards and eu directives: s harmonized standards: iec 61000-3-12 s eu directives: 73/23/eec, council directive on equipment designed for use within certain voltage limits 93/68/eec, a...

  • Page 5

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com i table of contents 1 introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 safety warnings 3 . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 6

    Table of contents eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com ii retrieving the event log 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting power strategy 48 . . . . . . . . ....

  • Page 7

    Table of contents eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com iii 9 warranty 107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two-year limited warranty (us and canada) 107 . . . . . . . . . ....

  • Page 8

    Table of contents eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com iv.

  • Page 9

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 1 chapter 1 introduction the eaton ® 9130 uninterruptible power system (ups), part of the powerware ® series, protects your sensitive electronic equipment from the most common power problems, including power failures, po...

  • Page 10

    Introduction eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 2 figure 1 shows the eaton 9130 rackmount ups, and figure 2 shows the optional rackmount ebm. Figure 1. The eaton 9130 rackmount ups figure 2. The eaton 9130 rackmount ebm figure 3 shows the eaton 9130 tower...

  • Page 11: Save These Instructions

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 3 chapter 2 safety warnings important safety instructions save these instructions this manual contains important instructions that you should follow during installation and maintenance of the ups and batteries. Please re...

  • Page 12: Sikkerhedsanvisninger

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 4 c a u t i o n s batteries can present a risk of electrical shock or burn from high short-circuit current. Observe proper precautions. Servicing should be performed by qualified service personnel knowled...

  • Page 13: Bewaar Deze Instructies

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 5 a d v a r s e l s batterierne kan give risiko for elektrisk stød eller brandsår forårsaget af høj kortslutningsstrøm. Overhold gældende forsigtighedsregler. Servicering skal udføres af kvalificeret serv...

  • Page 14: Tarkeita Turvaohjeita

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 6 s de uitgangsoverstroombeveiliging en de stroomonderbreker moeten door derden worden geleverd. S om aan de internationale normen en bedradingsvoorschriften te voldoen mag de gehele apparatuur die op de ...

  • Page 15: Consignes De Sécurité

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 7 s pienennä tulipalon vaaraa kytkemällä vain piiriin, jossa on 100 ampeerin maksimihaarapiirin ylivirtasuoja kansallisen sähkölainsäädännön (ansi/nfpa 70) mukaan. S muiden on toimitettava lähdön ylivirta...

  • Page 16: Sicherheitswarnungen

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 8 s afin de réduire les risques d'incendie, ne raccordez qu'à un circuit muni d'une protection de surintensité du circuit de dérivation maximum de 100 ampères conformément au nec (code Électrique national...

  • Page 17: Avvisi Di Sicurezza

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 9 a c h t u n g s dieses usv (unterbrechungsfreies stromversorgungssystem) enthält eine eigene energiequelle (batterien). Der usv-ausgang kann spannung führen, auch wenn das usv nicht an eine wechselstrom...

  • Page 18

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 10 p e r i c o l o la tensione contenuta in questo gruppo statico di continuità è letale. Tutte le operazioni di riparazione e di manutenzione devono essere effettuate esclusivamente da personale tecnico ...

  • Page 19: Gjem Disse Instruksjonene

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 11 viktig sikkerhetsinformasion viktige sikkerhetsinstruksjoner gjem disse instruksjonene denne håndboken inneholder viktige instruksjoner som du bør overholde ved montering og vedlikehold av ups-enheten ...

  • Page 20: Regulamentos De Segurança

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 12 regulamentos de segurança instruÇÕes de seguranÇa importantes guarde estas instruÇÕes este manual contém instruções importantes que devem ser seguidas durante a instalação e manutenção do no-break e da...

  • Page 21

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 13 Ïðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòè ÀÆÍÛÅ ÓÊÀÇÀÍÈß ÏÎ ÌÅÐÀÌ ÁÅÇÎÏÀÑÍÎÑÒÈ ÑÎÕÐÀÍÈÒÅ ÝÒÈ ÓÊÀÇÀÍÈß äàííîì ðóêîâîäñòâå ñîäåðæàòñÿ âàæíûå èíñòðóêöèè ïî óñòàíîâêå è îáñëóæèâàíèþ èñòî÷íèêà áåñïåðåáîéíîãî ïèò...

  • Page 22: Advertencias De Seguridad

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 14 Î Ñ Ò Î Ð Î Æ Í Î s ûñîêîå íàïðÿæåíèå, âûçâàííîå êîðîòêèì çàìûêàíèåì â áàòàðåå, ìîæåò ïðèâåñòè ê ïîðàæåíèþ ýëåêòðè÷åñêèì òîêîì èëè îæîãó. Ñîáëþäàéòå ìåðû ïðåäîñòîðîæíîñòè. Òåõíè÷åñêîå îáñëóæèâàíèå äîëæ...

  • Page 23: Säkerhetsföreskrifter

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 15 s la protección contra sobrecorriente de salida y el conmutador de desconexión debe suministrarse por parte de terceros. S para cumplir con los estándares internacionales y las normas de instalación, l...

  • Page 24

    Safety warnings eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 16 s för att reducera faran för brand får anslutning endast utföras till en krets som skyddas med överbelastningsskydd på maximalt 100 ampere i enlighet med nec, ansi/nfpa 70. S utgående överbelastningssy...

  • Page 25: Inspecting The Equipment

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 17 chapter 3 installation this section explains: s equipment inspection s unpacking the cabinet s checking the accessory kit s cabinet installation (rackmount and tower) s wiring installation s initial startup inspecting...

  • Page 26: Unpacking The Cabinet

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 18 unpacking the cabinet c a u t i o n s unpacking the cabinet in a low-temperature environment may cause condensation to occur in and on the cabinet. Do not install the cabinet until the inside and outside ...

  • Page 27: Rackmount Installation

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 19 rackmount installation the eaton 9130 rackmount cabinet comes with all of the hardware required for installation in a standard eia or jis seismic rackmount configuration with square and round mounting hol...

  • Page 28

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 20 rackmount setup c a u t i o n s the cabinet is heavy (see page 78). Removing the cabinet from its carton requires a minimum of two people. S if installing optional ebm(s), install the ebm(s) directly belo...

  • Page 29

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 21 2. Select the proper holes in the rack for positioning the ups in the rack (see figure 5). The rails occupy four positions on the front and rear of the rack. 3. Secure one rail assembly to the front of th...

  • Page 30

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 22 note there are two sets of four mounting holes on each side of the ups: a forward position and a middle position. Choose the position that meets your configuration needs. Mounting bracket m4 8 flat-head s...

  • Page 31

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 23 13. Optional. Insert a rear stop bracket through the inside of each rail behind the ups. Rotate each bracket and slide the bracket until it fits tightly against the ups's rear panel. Secure each bracket t...

  • Page 32

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 24 note a ribbon cable connects the lcd control panel to the ups. Do not pull on the cable or disconnect it. Note leave ribbon cable connected. Figure 9. Removing the ups right front cover c a u t i o n a sm...

  • Page 33

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 25 up to 1500 va models 2000–3000 va models figure 10. Connecting the ups internal batteries 3. If you are installing ebms, see the following section, “connecting the ebm(s),” before continuing with the ups ...

  • Page 34

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 26 connecting the ebm(s) to install the optional ebm(s) for a ups: 1. On the bottom of the ups right front cover, remove the ebm cable knockout (see figure 11). Note use care to protect the lcd control panel...

  • Page 35

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 27 bottom ebm cable knockout (underneath cover) top ebm cable knockout ebm cover hook figure 12. Removing the ebm front cover 3. For the bottom (or only) ebm, remove the ebm cable knockout on the top of the ...

  • Page 36

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 28 c a u t i o n a small amount of arcing may occur when connecting an ebm to the ups. This is normal and will not harm personnel. Insert the ebm cable into the ups battery connector quickly and firmly. 5. P...

  • Page 37: Tower Installation

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 29 7. Replace the ebm front cover. To replace the cover, verify that the ebm cables are routed through the ebm cover knockouts, then slide the cover from the left to the right until it connects with the cove...

  • Page 38: Tower Wiring Installation

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 30 tower wiring installation this section explains: s installing the ups, including connecting the ups internal batteries s connecting any optional ebms installing the ups note do not make unauthorized chang...

  • Page 39

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 31 c a u t i o n a small amount of arcing may occur when connecting the internal batteries. This is normal and will not harm personnel. Connect the cables quickly and firmly. 2. Connect the internal battery ...

  • Page 40

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 32 6. If you are installing power management software, connect your computer to one of the communication ports or optional connectivity card (see page 53). For the communication ports, use an appropriate cab...

  • Page 41

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 33 1000–1500 va models 2000–3000 va models remove cable retention clip. Plug in ebm cable. Rotate clip. Reinstall cable retention clip. Figure 16. Connecting the ebms.

  • Page 42: Ups Initial Startup

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 34 ups initial startup to start up the ups: note verify that the total equipment ratings do not exceed the ups capacity to prevent an overload alarm. 1. Verify that the internal batteries are connected. Rack...

  • Page 43

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 35 10. Verify that the indicator illuminates solid, indicating that the ups is operating normally and any loads are powered. The ups should be in normal mode. 11. Press the esc button until the start screen ...

  • Page 44

    Installation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 36.

  • Page 45: Control Panel Functions

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 37 chapter 4 operation this chapter contains information on how to use the eaton 9130, including front panel operation, operating modes, ups startup and shutdown, transferring the ups between modes, retrieving the event ...

  • Page 46

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 38 table 1 shows the indicator status and description. Table 1. Indicator descriptions indicator status description green on the ups is operating normally. Flashing a new information message is active. Yellow o...

  • Page 47

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 39 table 2 shows the basic menu structure. Table 2. Menu map for display functions main menu submenu display information or menu function ups status main status (mode and load) / notice or alarm status (if any)...

  • Page 48

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 40 user settings the following table displays the options that can be changed by the user. Table 3. User settings description available settings default setting change language [english] [french] [spanish] [ger...

  • Page 49

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 41 table 3. User settings (continued) default setting available settings description frequency converter [enabled] [disabled] if enabled, the ups operates as a frequency converter, with bypass operation and all...

  • Page 50

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 42 table 3. User settings (continued) default setting available settings description site wiring fault alarm [enabled] [disabled] an active site wiring fault alarm prevents startup or, if operating, forces oper...

  • Page 51: Operating Modes

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 43 table 3. User settings (continued) default setting available settings description predictive maintenance notices [enabled] [disabled] enabled remote emergency power-off (repo) input polarity [open] [closed] ...

  • Page 52

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 44 if battery capacity becomes low while in battery mode, the indicator flashes slowly and the audible alarm beeps once every second. If the “battery low” alarm is set, the indicator also illuminates solid. Thi...

  • Page 53: Ups Startup and Shutdown

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 45 standby mode when the ups is turned off and remains plugged into a power outlet, the ups is in standby mode. The indicator is off, indicating that power is not available to your equipment. The battery rechar...

  • Page 54

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 46 5. Check the ups front panel display for active alarms or notices. Resolve any active alarms before continuing. See “troubleshooting” on page 101. If the indicator is on, do not proceed until all alarms are ...

  • Page 55: Retrieving  The Event Log

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 47 ups shutdown to shut down the ups: 1. Press the button on the front panel for three seconds. The ups starts to beep and shows a status of “ups off pending...”. The ups then transfers to standby mode, and the...

  • Page 56: Setting Power Strategy

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 48 setting power strategy on the high efficiency setting, the ups operates normally on bypass, transfers to inverter in less than 10 ms when utility fails, and transfers back to bypass in 1 minute after utility...

  • Page 57: Configuring Load Segments

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 49 you can prohibit bypass (”never”) or always allow bypass with no specification checking (”always”). For “always on ups fault,” transfer to bypass is always made on ups fault; otherwise, operation proceeds as...

  • Page 58

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 50 to set the restart and shutdown delay times for each load segment: 1. Press any button to activate the menu options, then select settings, user settings and automatic start delay. 2. Set the restart delay fo...

  • Page 59

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 51 configuring battery settings set the ups for the number of ebms installed, whether to run automatic battery tests, and automatic restart configuration. Configuring the ups for ebms to ensure maximum battery ...

  • Page 60

    Operation eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 52 running automatic battery tests automatic battery tests run approximately every 30 days, unless disabled. During the test, the ups transfers to battery mode and discharges the batteries for 25 seconds under ...

  • Page 61

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 53 chapter 5 communication this section describes the: s communication ports (rs-232 and usb) s connectivity cards s remote emergency power-off (repo) s relay output contacts s programmable signal inputs s modem operatio...

  • Page 62: Communication Options

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 54 installing communication options and control terminals to install the communication options and control terminals: 1. Install the appropriate connectivity card and/or necessary cable(s) and connect the c...

  • Page 63

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 55 when the communication cable is installed, power management software can exchange data with the ups. The software polls the ups for detailed information on the status of the power environment. If a power...

  • Page 64

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 56 connectivity cards connectivity cards allow the ups to communicate in a variety of networking environments and with different types of devices. The eaton 9130 has one available communication bay for the ...

  • Page 65

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 57 note for europe, the emergency switch requirements are detailed in harmonized document hd-384-48 s1, “electrical installation of the buildings, part 4: protection for safety, chapter 46: isolation and sw...

  • Page 66

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 58 relay output contacts the ups incorporates three programmable relay outputs with potential free contacts for remote alarm indications: a standard relay port and two outputs in the rs-232 communication po...

  • Page 67

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 59 programmable signal inputs the ups incorporates four programmable signal inputs: one rs-232 input, two connectivity card inputs, and one repo terminal input. See figure 18 on page 53 for the locations of...

  • Page 68: Modem Operation

    Communication eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 60 modem operation to configure the ups and modem handling features for remote monitoring and service, contact your service representative. Powerware lansafe power management software each eaton 9130 ups sh...

  • Page 69: Ups And Battery Care

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 61 chapter 6 ups maintenance this section explains how to: s care for the ups and batteries s replace the ups internal batteries and extended battery modules (ebms) s test new batteries s recycle used batteries or ups s ...

  • Page 70: When To Replace Batteries

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 62 storing the ups and batteries if you store the ups for a long period, recharge the battery every 6 months by connecting the ups to utility power. The internal batteries charge to 90% capacity in less t...

  • Page 71

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 63 s do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes and may be extremely toxic. S determine if the battery is inadvertently grounded. If inadvertent...

  • Page 72

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 64 note leave ribbon cable connected. Figure 23. Removing the ups right front cover 2. Disconnect the internal battery connector (see figure 24). 3. Up to 1500 va models only. If the ebm cable is not conn...

  • Page 73

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 65 5. Carefully pull the handle on the battery tray and slide the battery package slowly out onto a flat, stable surface; use two hands to support the battery package. See “recycling the used battery or u...

  • Page 74

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 66 replacing tower ups internal batteries c a u t i o n the ups internal batteries are heavy (see page 78). Use caution when handling the heavy batteries. The internal batteries are located behind the ups...

  • Page 75

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 67 2. Remove and retain the two screws holding the internal battery connector. Disconnect the internal battery connector. See figure 26. Battery cover plate internal battery connector battery tray handle ...

  • Page 76

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 68 6. Replace the battery cover plate into the slots at left, threading the battery connector through the access slot. Reinstall the retained screws. C a u t i o n a small amount of arcing may occur when ...

  • Page 77

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 69 replacing rackmount ebms c a u t i o n the ebm is heavy (see page 78). Lifting the cabinet into the rack requires a minimum of two people. To replace the ebms: 1. Remove the front cover of each ebm. Se...

  • Page 78

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 70 2. Unplug the ebm cable from the ups. If additional ebms are installed, unplug the ebm cable from the battery connector on each ebm. 3. If not already installed, install the supplied mounting brackets ...

  • Page 79

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 71 10. Replace the ebm front cover. To replace the cover, verify that the ebm cables are routed through the ebm cover knockouts, then slide the cover from the left to the right until it connects with the ...

  • Page 80: Testing New Batteries

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 72 5. For each cable retention clip removed, rotate the clip and install it under each ebm cable connection using the retained screws. 6. Verify that the ebm connections are tight and that adequate bend r...

  • Page 81: Updating The Ups Firmware

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 73 recycling the used battery or ups contact your local recycling or hazardous waste center for information on proper disposal of the used battery or ups. W a r n i n g s do not dispose of the battery or ...

  • Page 82

    Ups maintenance eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 74.

  • Page 83: Model Specifications

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 75 chapter 7 specifications model specifications this section provides the following specifications: s communication options s model lists s weights and dimensions s electrical input and output s environmental and safety...

  • Page 84

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 76 table 10. Ups model list (rackmount models) model power level rear panel diagram pw9130l700r-xl2u 700 va / 630w figure 28 on page 91 pw9130l1000r-xl2u 1000 va / 900w figure 28 on page 91 pw9130l1500r-xl...

  • Page 85

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 77 table 11. Ups model list (tower models) model power level rear panel diagram pw9130l700t-xl 700 va / 630w figure 43 on page 95 pw9130l1000t-xl 1000 va / 900w figure 44 on page 95 pw9130l1500t-xl 1500 va...

  • Page 86

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 78 table 12. Weights and dimensions (rackmount models) model (rackmount ups) dimensions (h w d) weight pw9130l700r-xl2u pw9130l1000r-xl2u pw9130g1000r-xl2u pw9130i1000r-xl2u pw9130g1000r-xl2ueu pw9130g1000...

  • Page 87

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 79 table 13. Weights and dimensions (tower models) model (tower ups) dimensions (h w d) weight pw9130l700t-xl pw9130i700t-xl pw9130g700t-xlau 231* 160 354 mm (9.09”* 6.30” 13.94”) 12.2 kg (26.9 lb) pw9130l...

  • Page 88

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 80 table 15. Electrical input (rackmount models) model default input (voltage/current) selectable input voltages voltage range at 100% load pw9130l700r-xl2u 120v / 5.8a 100*, 110**, 120, 127 80–138 vac pw9...

  • Page 89

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 81 table 16. Electrical input (tower models) model default input (voltage/current) selectable input voltages voltage range at 100% load pw9130l700t-xl 120v / 5.8a 100*, 110**, 120, 127 80–138 vac pw9130l10...

  • Page 90

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 82 table 17. Electrical input connections (rackmount models) model input connection input cable pw9130l700r-xl2u 5-15p attached line cord pw9130l1000r-xl2u 5-15p attached line cord pw9130l1500r-xl2u 5-15p ...

  • Page 91

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 83 table 18. Electrical input connections (tower models) model input connection input cable pw9130l700t-xl 5-15p attached line cord pw9130l1000t-xl 5-15p attached line cord pw9130l1500t-xl 5-15p attached l...

  • Page 92

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 84 table 19. Electrical output (all models) all models normal mode battery mode voltage regulation ±2% nominal output voltage ±3% efficiency >95% (high efficiency mode), >88% >79.5% (700 va), >82% (1000–15...

  • Page 93

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 85 table 20. Electrical output connections (rackmount models) model output connections output cables pw9130l700r-xl2u (6) 5-15r none pw9130l1000r-xl2u (6) 5-15r none pw9130l1500r-xl2u (6) 5-15r none pw9130...

  • Page 94

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 86 table 21. Electrical output connections (tower models) model output connections output cables pw9130l700t-xl (6) 5-15r none pw9130l1000t-xl (6) 5-15r none pw9130l1500t-xl (6) 5-15r none pw9130l2000t-xl ...

  • Page 95

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 87 table 22. Environmental and safety (all models) 120 vac models 208/230/240 vac models surge suppression ansi c62.41 category b3 (6 kv ring and combination) en 61000-2-2 en 61000-4-2, level 3 en 61000-4-...

  • Page 96

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 88 table 23. Battery runtimes (in minutes) at 100% load (rack models) model internal batteries + 1 ebm + 2 ebms + 3 ebms + 4 ebms pw9130l700r-xl2u 9 41 72 105 130 pw9130l1000r-xl2u 5 30 55 83 108 pw9130g10...

  • Page 97

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 89 table 24. Battery runtimes (in minutes) at 100% load (tower models) model internal batteries + 1 ebm + 2 ebms + 3 ebms + 4 ebms pw9130l700t-xl pw9130i700t-xl pw9130g700t-xlau 6 n/a n/a n/a n/a pw9130l10...

  • Page 98

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 90 table 25. Battery internal batteries ebms rackmount configuration 700–1000 va models: 36 vdc (3 12v, 9 ah) 1500 va models: 48 vdc (4 12v, 9 ah) 2000–3000 va models: 72 vdc (6 12v, 9 ah) pw9130n1000r-ebm...

  • Page 99: Rear Panels

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 91 rear panels this section shows each model's rear panel. Receptacles in load segment 1 are shaded. Table 10 on page 76 lists the rackmount models. Table 11 on page 77 lists the tower models. Input and ou...

  • Page 100

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 92 figure 31. Model pw9130g1000r-xl2uau figure 32. Model pw9130g1500r-xl2uau figure 33. Model pw9130l1500r-xl2u figure 34. Model pw9130i1500r-xl2u.

  • Page 101

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 93 figure 35. Model pw9130l2000r-xl2u figure 36. Model pw9130g2000r-xl2u figure 37. Models pw9130i2000r-xl2u, pw9130g2000r-xl2ueu figure 38. Model pw9130g2000r-xl2uau.

  • Page 102

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 94 figure 39. Models pw9130l2500r-xl2u, pw9130l3000r-xl2u figure 40. Models pw9130g2500r-xl2u, pw9130g3000r-xl2u figure 41. Models pw9130g2500r-xl2ueu, pw9130i3000r-xl2u, pw9130g3000r-xl2ueu figure 42. Mod...

  • Page 103

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 95 figure 43. Model pw9130l700t-xl figure 44. Model pw9130l1000t-xl figure 45. Model pw9130l1500t-xl figure 46. Model pw9130l2000t-xl.

  • Page 104

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 96 figure 47. Model pw9130l3000t-xl figure 48. Model pw9130g1000t-xl figure 49. Model pw9130g2000t-xl figure 50. Model pw9130g3000t-xl.

  • Page 105

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 97 figure 51. Model pw9130i700t-xl figure 52. Model pw9130g1000t-xleu and pw9130i1000t-xl figure 53. Model pw9130i1500t-xl figure 54. Models pw9130g2000t-xleu and pw9130i2000t-xl.

  • Page 106

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 98 figure 55. Models pw9130g3000t-xleu and pw9130i3000t-xl figure 56. Model pw9130g700t-xlau figure 57. Model pw9130g1000t-xlau figure 58. Model pw9130g1500t-xlau.

  • Page 107

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 99 figure 59. Model pw9130g2000t-xlau figure 60. Model pw9130g3000t-xlau.

  • Page 108

    Specifications eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 100

  • Page 109

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 101 chapter 8 troubleshooting the eaton 9130 is designed for durable, automatic operation and also alerts you whenever potential operating problems may occur. Usually the alarms shown by the control panel do not mean tha...

  • Page 110

    Troubleshooting eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 102 to check the event log for a history of conditions: 1. Press any button on the front panel display to activate the menu options. 2. Press the button until event log displays. 3. Press the enter button...

  • Page 111

    Troubleshooting eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 103 action possible cause alarm or condition overload led is on. 1 beep every second. Power requirements exceed the ups capacity (greater than 100% of nominal; see page 84 for specific output overload ran...

  • Page 112

    Troubleshooting eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 104 action possible cause alarm or condition the ups does not start. The power cord is not connected correctly. Check the power cord connections. The remote emergency power-off (repo) switch is active or ...

  • Page 113: Silencing The Alarm

    Troubleshooting eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 105 silencing the alarm press any button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes,...

  • Page 114

    Troubleshooting eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 106.

  • Page 115

    Eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 107 chapter 9 warranty two-year limited warranty (us and canada) powerware ups models: 3105, 9120, 9125, 9130, 9140, and ferrups ® up to 3.1 kva warrantor: the warrantor for the limited warranties set forth herein is eat...

  • Page 116

    Warranty eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 108 what this limited warranty does not cover: this warranty does not cover any defects or damages caused by: (a) failure to properly store the product before installation, including the charge of batteries no l...

  • Page 117

    Warranty eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 109 costs not related to warranty: the end-user shall be invoiced for, and shall pay for, all services not expressly provided for by the terms of this warranty, including without limitation, site calls involving...

  • Page 118

    Warranty eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 110 what this limited warranty does not cover: this warranty does not cover any defects or damages caused by: (a) failure to properly store the product before installation, including the charge of batteries no l...

  • Page 119

    Warranty eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 111 other limitations: company's obligations under this warranty are expressly conditioned upon receipt by company of all payments due to it (including interest charges, if any). During such time as company has ...

  • Page 120

    Warranty eaton ® 9130 ups (700–3000 va) user's guide s 164201718 rev 2 www.Powerware.Com 112 what this guaranty does not cover: any reimbursement or repair to end-user's equipment does not include reimbursement for or restoration of any data loss. This guaranty does not cover any defects or damages ...