Technical Description
Eb e rsp a c h e r '
Operating Instructions
Installation Instructions
J . Eberspa-sher
GmbH & Co.
Eoerspachersr.r 24
D -7373Q Esslingen
Tole-fon (2entral)
(0711)9 39-03
Telefax
(0? 11)939-0500
vwrt.cberspaechw.dQ
Engine-independent air heaters
B 1 L C
compact
for gasoline
D 1 L C
compact
for diesel fuel
with integrated control unit
Specifications (margin of error ± 10%)
Heating medium
Fuel
Heating capacity
control
Heating capacity”
Air
Gasoline
(commercially available) or
diesel fuel
(commercially available)
High / Medium / Low / Off
Power High
Medium Low
2200
1800
1200
850 W
Hot air throughput4*
110
95
65
65 kg/h
Fuel consumption
B 1 L C
compact
0,30
0,24
0,16
0,12 l/h
D 1 L C
compact
0,27
0,21
0,14
0,10 l/h
Rated voltage
Operating range
Minimum voltage21
Maximum voltage31
12 V o r 24 V
10,5V or 21 V
16 V o r 32 V
Air heater
B 1 L C
compact
D 1 L C
compact
D 1 L C
compact
Cat. No.
12V 20 1 7 6 6 0 5 0 0 0 0
1 2 V 2 5 1 9 7 6 0 5 0 0 0 0
24 V 25 1977 05 00 00
Universal installation kit, operating and unit and heater
timers must be ordered separately as additional parts
(see page 2).
0 1 L C
compact,
complete
1 2 V 25 1979 05 00 00
D 1 L C
compact,
complete
24 V 25 1978 05 00 00
with universal installation kit and opening unit.
See Additional Parts Catalog for further accessories.
Electric power
consum ption11
gt start
B 1 L C
compact
12 V = 250 W
D 1 L C
compact
12 V = 250 W
24 V = 210 W
in operation
Power / High
30
22
/ Medium
10
/ Low
10W
Radio interference
suppression level 3
Weight
Am bient temperature
D 1 L C
compact
B 1 L C
compact
Additional radio inter
ference suppression
measures possible
approx. 3.5 kg
in operation
- 40 °C to
+
70 °C
- 40 °C to 4- 50 °C
not in operation
- 40°C to + 85 °C
1) at rated voltage.
an undervoltage safety device built into the control
unit switches off the heater at about 10.5 V. or 21 V.
3) an overvoltage safety device built into the control
unit switches off the heater at about 16 V or 32 V.
4) without backpressure.
25 1976 90 94 C6
07.2030
Subject to change
Printed In Germany
© J. Eberspacher GmbH & Co.
B39