Eberspächer B1LC compact Operating Instructions Manual - page 14
Circuit diagram, control elements
(Tip
QlM?|3Ml5|t|?T7iro
Parts list
2.15.1 Sensor, room temperature
2.15.9 Sensor, outside temperature
3.1.11 Operating unit
3.1.16 Momentary-contact switch
3.2.8 Module clock
3.2.12 Timer
3.3.6 Radio receiver
3.9.1 Diagnosis unit, JE diagnosis
a) Connect the control elements to the heater
• rt
Supply plus terminal 30
• ge
Switch-on signal S+
• gr
Temperature - actual value
• wsrt S w itci off theft warning system
• br
Supp y minus terminal 31
• blws Diagnosis
• grrt Temperature - target value
• brws Connection to earth for external temperature
sensor and temperature target value
b) Terminal 15 - necessary when connecting TP 4
c) Lighting terminal 58
d) Connection for diagnosis unit
e) Connection for external temperature sensor
g) Connection for external heater key ®
h) Connection for TP4 remote control
j) Connection for outside temperature sensor
k) When connecting an automatic switch or radio
receiver - cut open wire at this point
I) Connection change-over switch ‘heating /
ventilating’ (optional). How to start: operate
change-over switch ‘heating / ventilating’,
then switch on the heater.
Cable ends that are not being used must be insulated.
Plug and socket case are shown from the cable entry
side.
Cable colours
sw = black
25 1 895 00 97 02 A
_ vvhite
rt = red
ge = yellow
gn - green
vi = violet
br - brown
gr = grey
bl = blew
li
= purple