Eberspächer B1LC compact Operating Instructions Manual - page 7
Installing the heater
The B 1 L C
c o m p a c t!
D 1 L C
compact
heaters are suitable
and approved fo r installation in vehicle areas used by per
sons. Installation in the driver or passenger areas of motor
buses* is not permitted.
The electronic control device is integrated in the heater. This
facilitates wiring during installation
The heaters are suitable for installation in cabins of vehicles
transporting hazardous goods and, if wired with the appro
priate cable harness (see wiring diagram), meet TRS 003.
For this reason the heater must be fitted by its base on an
outside panel of the vehicle or on the vehicle floor, using the
seal seated on the base.
The factory plate must be clearly visible when the heater is
installed. If necessary a second plate (duplicate) with the
same information as the original can be affixed to a point on
the heater clearly visible after installation or to a cover loca
ted in front of the heater. A second plate is not necessary if
the original is visible after removal of a cover without the aid
of tools.
* Vehicles with more than 9 seats.
Principal Dimensions
360
Permissible installation positions
%
rar
The heater should be installed in the standard position as
shown. See sketch for maximum permissible deviations.
Please consult the manufacturer if further differences are re
quired.
During starting and thermostatic operation a heater installed
in the standard position may deviate, due to the inclination
of the vehicle during motion, up to ± 15° in both axes from
the standard position.
Continuous heating operation after starting is possible at a
deviation of up to ± 30° from the standard position. With
deviations exceeding ± 30° reliable heating operation is no
longer possible. However, this does not lead to damage of
the heater if the changes in the operating position are only
fo r brief periods.
Important; the plug connection must always point
upwards.