VEhICLE hEATERs – TEChnICAL DOCuMEnTATIOn | 13
4 WhAT TO DO IF …?
pOssible displays in the eVent Of a fault
DIspLAy
DEsCRIpTIOn
REMEDy / WORkshOp
Automatic detection is active.
The Easystart select has been
disconnected from the power
supply and then reconnected.
Wait until the automatic detec-
tion has finished.
heater fault
Easystart select fault
perform the diagnosis.
Check Easystart select, replace
if necessary.
note:
Display OFF with LOngpREss on
button.
heater OFF - undervoltage
applied.
Charge the battery.
Check the voltage supply.
note:
Display OFF with LOngpREss on
button.
no communication.
Check and if necessary renew
the heater fuse.
Check the voltage supply.
Check the wiring.
Display if no diagnostic cable
is connected.
Connect diagnostic cable.