AIR FILTER
•
Clean before Use.
- Remove air cleaner cover and pull out
air fillter.
- Lightly brush off dust or wash it in water
and detergent.
- Dry completely before putting it back in
place.
Fuel filter
Cap
•
Check periodically.
- The standard spark gap is 0.6 ~ 0.7 mm
(0.024 ~ 0.028 in.).
- Correct spark gap if it is wider or narrower
than the standard gap.
- If the electrodes are coated with carbon
deposites replace with a new spark plug.
Do not sandblast to clean.
Remainnig sand will damage engine.
•
Fastening torque = 145 ~ 155 kgf-cm (125
~ 135 in-lb)
SPARK PLUG
FUEL FILTER
• Check periodically.
- Do not allow dust to enter into fuel tank.
- Clogged filter will cause difficulty in
starting engine or poor engine
parformances.
- Pick up fuel strainer through fuel inlet
port with a piece of steel wire or the like.
- When filter is dirty, replace it.
Air filter
Air cleaner cover
IMPORTANT
Do not over tighten plug.
0.6 ~ 0.7 mm ( .024 ~ .028 in.)