Eco Air ECO2406SD Installation manual

Other manuals for ECO2406SD: User Manual
Manual is about: R410A SPLIT SERIES DC INVERTER

Summary of ECO2406SD

  • Page 1

    Before using your air conditioner, please read this manual carefully and keep it for future reference. Before using your air conditioner, please read this manual carefully and keep it for future reference. Before using your air conditioner, please read this manual carefully and keep it for future re...

  • Page 2

    Disposal disposal: do not dispose this product as unsorted waste. It is prohibited to dispose of this appliance in domestic household waste. For disposal, : a) contact your local council for disposal. B) the manufacture will take back the old appliance for disposal when you replace with a new produc...

  • Page 3: Contents

    1 contents safety precautions warning ............................................................................................................................................2 caution ...................................................................................................................

  • Page 4

    2 disposal disposal: do not dispose this product as unsorted waste. It is prohibited to dispose of this appliance in domestic household waste. For disposal, : a) contact your local council for disposal. B) the manufacture will take back the old appliance for disposal when you replace with a new prod...

  • Page 5

    2 warning read the follow safety precautions carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating and main circuit for the model to be installed. Incorrect installation due to ignoring of the instruction will cause harm or dama...

  • Page 6

    3 selecting installation place read completely, then follow step by step. Indoor unit do not expose the indoor unit to heat or steam. Select a place where there are no obstacles in front or around the unit. Make sure that condensation drainage can be conveniently routed away. Do not install near a d...

  • Page 7

    4 accessories installation instructions note: except the above parts provided, the other parts needed during installation you must purchase. This illustration is for explanation purposes only. Copper lines must be insulated independently fig.3 ensure that the space around the left and right of the i...

  • Page 8

    5 installation instructions indoor unit installation 2. Drill a hole in the wall fig.4 note: 1. Fit the installation plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, dril...

  • Page 9

    6 installation instructions 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. Explain to clients that the pipe cover must be kept as it may be used when relocate the air conditioner to any other place. 2. For the rear-right-hand and rear-left-hand piping, install...

  • Page 10

    7 installation instructions 5. Piping and wrapping bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in fig.11. Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room. Do not put anything else in the box. Ind...

  • Page 11

    8 refrigerant pipe connection settlement of outdoor unit anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount. Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble th...

  • Page 12

    9 electrical work bar copper pipe clamp handle red arrow mark cone yoke handle bar "a " c: putting nut on remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.(not possible to put them on after flaring work) flare nut copper tube fig.17 fig....

  • Page 13

    10 connect the cable to the outdoor unit note: the supply voltage must be consistent with the rate voltage of the air conditioner. Electrical work 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identifie...

  • Page 14

    After the confirmation of the above conditions, prepare the wiring as follows: 1) never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) the screw which fasten the wi...

  • Page 15

    When relocate the unit to another place, perform evacuation using vacuum pump. Make sure the refrigerant added into the air conditioner is liquid form in any case. (not applicable to the units with r22 ) open the valve stem until it hits against the stopper. Do not try to open it further. Securely t...

  • Page 16

    Perform the electric safe check after completing installation: 1. Insulated resistance the insulated resistance must be more than 2m . 2. Grounding work after finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resis...

  • Page 17: Memo

    Memo date of installation: purchased from (dealer name): date of purchase: model number: serial number:.

  • Page 18

    Copyright reserved one (1)year limited warranty save this warranty information ecoair guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically exclud...