Eco Air ECO2406SD Installation manual - page 7
4
Accessories
INSTALLATION INSTRUCTIONS
Note: Except the above parts provided, the other parts needed during
installation you must purchase.
This illustration is for explanation purposes only.
Copper lines must be insulated independently
Fig.3
Ensure that the space around the left and
right of the indoor unit is more than 12cm.
The indoor unit should be installed allowing
a minimum clearance of 15cm from the
ceiling.
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
A minimum pipe run of 3 metres is required
to minimise vibration & excessive noise.
The indoor unit should be installed on the
wall at a height of 2.3 metres or more from
the floor .
Two of the A, B and C directions should be
free from obstructions.
CAUTION
.
2
Seal (See Page 8 for details)
1
(See page 8 for details)
1
8
8
1
1
1
Self-tapping screw B
ST2.9x10-C-H
Remote controller
holder
8
9
Self-tapping Screw B ST2.9X10
Remote controller
Installation Plate
Name of Accessories
Self-tapping Screw A ST3.9X25
Drain Joint
Connecting
pipe Assembly
Clip Anchor
Number
Q
ty
Remote controller holder
Parts you must
purchase
(A minimum
pipe wall-thickness
of 0.7mm is required.)
9.52
16
Liquid side
Gas side
1
2
3
4
5
6
7
8
9
Loop the
connective
cable.
C
B
A
60cm
abo
ve
60cm
abo
ve
30cm
abov
e
200
cm
ab
ove
6
12cm above
Air Filte
r
Air Outlet
30c
m a
bov
e
12cm
abo
ve
15cm above
1
2
3
Water tray
2.3m above
Remote Controller
7
On/Off
Sleep
Fan
Swing
Air Direction
Timer On
Timer Off
Mode
Hr.
ON TIMER
Hr.
Off TIMER
SET TEMP
Auto