INSTALLATION INSTRUCTIONS
Indoor unit installation
2. Drill a hole in the wall
Fig.4
Note:
1. Fit the Installation Plate
1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete or
the like, drill eight (8) 5mm diameter holes
in the wall. Insert Clip anchor for appropriate
mounting screws.
3. Fit the installation plate on the wall with eight
(8) type “A” screws.
Fit the Installation Plate and drill holes in the wall according to the wall structure
and corresponding mounting points on the installation plate.
(Dimensions are in “mm” unless otherwise stated)
1. Determine hole positions according to
the diagram detailed in Fig.5. Drill
one (1) hole (
95mm) slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.
Wall
Indoor
Outdoor
5
-7
m
m
Fig.6
Fig.5
150mm or more from the ceiling
Indoor Unit Outline
120mm or more
from the wall
432
Hooked Part
432
1080
120mm or more
from the wall
3
3
0
108
130
95
95
130
5
0
5
0
2
2
Correct orientation
of Installation Plate