Controller Features / Options
4. Press SELECT again to display the “12 or 24 hr”
screen.
If you wish to change the fast rinse time, use the
UP () or DOWN (–) buttons to set the fast rinse
time between 1 and 30 minutes.
6. Press SELECT to return to the normal run (time of
day) screen.
12 OR 24 HOUR CLOCK: All time displays are
shown in 12 hour (AM/PM) format at the default
setting. If 24 hour time format is de sired, set to “24
hr” by pressing the UP () button.
5. Press SELECT again to display the “bA-” back-
wash time setting screen.
FIG. 30
FIG. 31
BACKWASH & FAST RINSE TIMES: If you expe-
rience salty tasting water after regeneration, you
may need to increase the backwash and fast rinse
times. You may increase or decrease the back-
wash and fast rinse times from their default values,
in 1 minute increments.
If you wish to change the backwash time, use the
UP () or DOWN (–) buttons to set the backwash
time between 1 and 30 minutes. Then press
SELECT to display the “Fr-” fast rinse time setting
screen.
FIG. 32
PROGRAM MEMORY
If electrical power to the softener is interrupted, the
time display is blank, but the electronic controller
keeps correct time for about 6 hours. When power is
restored, you must reset the present time only if the
display is flashing. All other settings are maintained
and never require resetting unless a change is
desired. If the time is flashing after a long power out-
age, the softener continues to work as it should to
provide you with soft water. However, regenerations
may occur at the wrong time of day until you reset the