Ecofires eko 2040 Installation And User Instructions Manual

Summary of eko 2040

  • Page 1

    Installation and user instructions all instructions must be handed to user for safekeeping revision a - 06/09 country(s) of destination - gb/ie eko 2 0 4 0 fuel effect gas fire.

  • Page 2

    Installation instructions preliminary notes before installation this appliance is an inset decorative fuel effect appliance which provides radi- ant warmth utilising the latest type burner technology. The fire is designed to fit into a purpose made builder’s opening, and use natu- ral draught flues ...

  • Page 3

    Important notes this fire is an inset live fuel effect gas fire providing radiant warmth. It is designed to operate on natural gas only. See data plate on appliance. It is the law that all gas appliances and fittings are installed by a competent [1] person and in accor- dance with the gas safety (in...

  • Page 4

    Installation requirements this appliance must not be installed into a room containing a bath or shower, or where steam maybe present. The fire has been designed to fit into a purpose made builders’ opening meeting certain dimen- sional requirements . The flue must have an effective height of at leas...

  • Page 5

    Installation requirements (continued) the flue must be connected to only one fireplace, and the flue must not vent more than one appliance (i.E. Not shared with a gas back boiler). There must be no opening in the flue apart from the one that the appli- ance is installed into, and the one venting the...

  • Page 6

    Site requirements (continued) a combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below. A non-combustible shelf may be fitted to within 10mm of the top edge of the fireplace opening. Combustible materials, such as wood, may be fitted to ...

  • Page 7

    Component checklist quantity description 1 burner tray assembly. 1 stone effect body. 1 bag of granular burner medium. 13 individually packaged ceramic pebbles. 1 set of manufacturers instructions. 1 screw and rawlplug pack. 1 fitting template. Installation of appliance notes: ensure that the gas su...

  • Page 8

    Operating the fire the pilot is visible at the rear of the fuel bed. The control knob is located on the right hand side of the appliance. Push in and turn the control knob to the spark position, and hold there for a few seconds. Continue turning anti-clockwise through the spark click to the pilot li...

  • Page 9

    Flue spillage monitoring system this fire is fitted with a flue spillage safety device (ods). If the fire shuts down during use for no apparent reason then several things may be suspected. If a door or window has been opened creating a draught, then pilot disturbance is the problem, and removal of t...

  • Page 10

    Servicing ensure that the fire is fully cold before attempting service. A suggested procedure for servicing is detailed below. 1. Lay out the dust sheet and tools. 2. Inspect the area around the top of the fireplace opening for signs of spillage. 3. Carefully remove the ceramic components and the up...

  • Page 11

    Troubleshooting guide fire sparks but pilot does not light no gas to fire, check isolators are open. Pipework blockage, clean out. Air not fully purged, repurge supply or wait longer. Spark earthing to metal work, reset gap correctly. Check for spilled granular burner medium in pilot well. Blocked p...

  • Page 12

    User instructions important notes the installation of this fire must only be carried out by a competent [1] person in accordance with the gas safety (installation and use) regulations 1998, the relevant british standards, codes of practice, the building regulations and the manufacturers’ instruction...

  • Page 13

    Clearances to combustibles a combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below. A non-combustible shelf may be fitted to within 10mm of the top of the fireplace opening. Combustible materials, such as wood, may be fitted to within 1...

  • Page 14

    Fuel bed layout (continued) 3. Next, place the pebbles marked ‘d’, ‘e’ and ‘f’ as shown. The letters are on the bottom of the pebbles and should face downwards. 3. Next, place the pebbles marked ‘g’ and ‘h’ as shown. The letters are on the bottom of the pebbles and should face down- wards. 3. Next, ...

  • Page 15

    Operating the fire the pilot is visible at the rear of the fuel bed. The control knob is located on the right hand side of the appliance. Push in and turn the control knob to the spark position, and hold there for a few seconds. Continue turning anti-clockwise through the spark click to the pilot li...