CLEARANCES TO COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions
given below.
A non-combustible shelf may be fitted to within 10mm of the top of the fireplace opening.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the
appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl
and embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is normally required for this appliance.
The requirements of other
appliances operating in the same space or room, and the results of a spillage test must be taken into con-
sideration when assessing ventilation requirements, this will have been carried out by your CORGI registered
installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.
FUEL BED LAYOUT
The appliance is supplied with 13 individually wrapped hand-finished ceramic pebbles and a bag of spheri-
cal ceramic beads - this is the granular burner medium, and the burner should be filled with this in the same
way as a conventional vermiculite type burner. There is approximately twice as much burner medium as is
required so the remainder should be retained by the user for future use, if required.
1. Fill the burner with the burner medium
so it is flat and level with the rim of the
burner.
Do not spill any down into the
pilot well as this could cause ignition
and or cross lighting problems.
2. Remove the pebbles from the protective
packaging. On the bottom of the pebbles
are the letters A to M. You will need to
select the pebbles in alphabetic order
beginning with ‘A’. Place the pebbles
marked ‘A’, ‘B’ and ‘C’ as shown. The let-
ters are on the bottom of the pebbles and
should face downwards.
2
2.0
3.0
4.0
A
C
B
Maximum depth of shelf
Minimum distance from finished
hearth surface to underside of shelf
100mm (4in)
745mm (29 1/4 in)
150mm (6in)
845mm (33 1/4 in)
203mm (8in)
895mm (35 1/4 in)
©
2009 Focal Point Fires plc.