EcoQuest LaundryPure Owner's Manual - page 4
4
10 Volt 60 Hz 15 AMP fuse or Circuit Breaker .
An individual branch circuit serving only the LaundryPure unit is recommended .
LaundryPure is equipped with a power cord .
never uSe an eXtenSion cord.
eLectricaL Ground iS reQuired on tHiS appLiance.
for your personal safety, this appliance must be grounded . this appliance is equipped with a
power cord having a 3-prong grounding plug for use in a properly installed and grounded outlet .
to minimize possible shock hazard, the power cord must be plugged into a mating, 3-prong,
ground-type outlet, grounded in accordance with local codes and ordinances . If a mating
outlet is not available, it is the personal responsibility and obligation of the customer to have the
properly grounded outlet installed by a qualified electrician .
As with most major appliances, use of a GfI (Ground fault Circuit Interrupt) is not recommended .
Water pressure of 10 to 75 psi is required to correctly operate your LaundryPure . Low water
pressure may prevent your unit from operating properly and/or cause a failure in your washing
machine’s water valve . the washer’s water valve may also not shut off completely . Check the
documentation supplied with your washing machine for exact specifications .
Your washing machine and cold water faucet must be within 4 feet of the right side of the unit to
use the inlet hose provided with your LaundryPure .
to avoid tHe poSSiBiLitY of water daMaGe, SHouLd a HoSe LeaK, aLwaYS Have faucetS
acceSSiBLe and turn off faucetS wHen waSHer iS not in uSe.
Water quality may affect the performance of your LaundryPure unit . If you have water quality
concerns such as high iron content or high chlorine content, consult a water filtration expert .
this system is designed for use on potable water systems only .
It is recommended the LaundryPure never be installed in areas where water may freeze since
the unit will always maintain some water in the unit, the water valve, and hose areas . this can
cause damage to internal components .
eLectricaL reQuireMentS
water reQuireMentS
Location conSiderationS
I N S t A L L A t I O N R E Q U I R E M E N t S
Electrical Shock Hazard .
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock . Check with a qualified electrician or serviceman if you are in doubt as to whether the
appliance is properly grounded . Do not modify the plug provided with the appliance - if it
will not fit the outlet, have a proper outlet installed by a qualified electrician .
warninG: