EcoSmart ES50LVP Installation, Operation And Maintenance Manual - Electrical
17 |
P a g e
ELECTRICAL
• WARNING - Make sure the installation meets all national and local
electrical codes.
Electrical Information
The ecosmart wiring diagram is located on the cover of the electrical box behind the lower front
panel. Ratings data is located on the lower front panel.
• The ecosmart operates on 120VAC 60Hz single phase line voltage
• All control circuits are standard 24VAC
• ecosmart must be grounded via the green wire within the control box
Electrical Connections Made to Quick Connects
• Stranded or solid wire may be used
• Male tab size on control board: 0.250 in x 0.032 in
• Correct female disconnects to mate with male tabs:
o Wire range: 22-18 AWG (Red) Panduit # DNF18-250 or equivalent
Wire range: 16-14 AWG (Blue) Panduit # DNF14-250 or equivalent
• Use a quality ratchet crimping tool to ensure reliable connections