EcoSmart ES50LVP Installation, Operation And Maintenance Manual - Pump Exerciser
27 |
P a g e
Pump Exerciser
• The circulating pump is exercised for 1 min every 24 hr when the ecosmart is OFF,
COOLING (Y), COOLING2 (Y2) or FAN (G) to prevent the possibility of ‘sticking’ due to
sediment and to meet local codes.
• During the 1 min pump on-time, the fan is turned off and resumes once the pump
exercising is completed
• Pump runs continuously if the outlet air temperature drops below 40F to prevent the
chance of freezing
SERVICE
AND
MAINTENANCE
NOTE: The ecosmart is not to be used for temporary heat during construction. Use for this
purpose will void equipment warranty.
Filter
Inspect the filter monthly and replace, remove and vacuum or rinse as required. A clogged or
inadequate filter may void product warranty. Replacement filter size is 16 x 20 x 1.
Coils
Air conditioning and heating coils should not require cleaning if the filter maintenance schedule
is adhered to. If a filter is damaged or collapses from plugging, dust may foul the coils. If this
happens, replace the filter and carefully vacuum the coils. The fan may need to be removed to
gain access to the face of the heating coil.
Fan and Motor
Check fan for dust once a year. If dirty, vacuum or wash to remove dust. Keeping the fan blades
clean will reduce noise and improve capacity and efficiency of the heating system.
Control and Blower Assembly Removal
1. Turn off main power.
2. Disconnect power, thermostat and any other miscellaneous wiring from the control
board and remove them from the control casing.