Ecoteck ILARIA Operation And Maintenance Manual

Summary of ILARIA

  • Page 1

    Pellet stove ilaria operation and maintenance manual www.Ecoteck.It pellet stove ilaria operation and maintenance manual www.Ecoteck.It.

  • Page 2

    Manual maintenance date operation performed manual ilaria maintenance date operation performed ilaria.

  • Page 3

    Manual ilaria manual manual manual ilaria ilaria ilaria important: carefully read this booklet, which describes all the steps required for the perfect operation of the pellet stove ilaria. Warning: the installation and operating norms described in this manual may differ from the regulations in other...

  • Page 4

    Manual manual manual manual ilaria ilaria ilaria ilaria -3- contents 1. Foreword ............................................................................................................................... 2. Safety information ........................................................................

  • Page 5

    Manual ilaria manual manual manual ilaria ilaria ilaria 7.5. Menu function ................................................................................................................. 7.5.1. Clock .....................................................................................................

  • Page 6

    Manual manual manual manual ilaria ilaria ilaria ilaria 1. Acknowledgement dear customer, we wish to thank you and congratulate you on your excellent choice. The ecoteck pellet stove ilaria will prove how quality and economy can go hand in hand with very high performance, reduced consumption and tot...

  • Page 7

    Manual ilaria manual manual manual ilaria ilaria ilaria in any case, check the firepot daily, as not all pellets have the same high quality standard. The glass is automatically cleaned by a flow of air; nonetheless, a slight grey film will tend to form on the glass after a few hours of operation. As...

  • Page 8

    Manual manual manual manual ilaria ilaria ilaria ilaria the cylindrical pellets have a diameter of 5 - 7 mm, a length that varies between 10 and 50 mm, and a weight of around 650 kg/m 3 . The low moisture content (8 - 10%) means they have a higher calorific value. The din 51731 standards define the ...

  • Page 9

    Manual ilaria manual manual manual ilaria ilaria ilaria -8- in any case, when a problem occurs, the pellet feed system is immediately stopped. There are two main “mechanical” safety devices: if one of these safety mechanisms is activated, the display will show the corresponding error code. 4.1. No f...

  • Page 10

    Manual manual manual manual ilaria ilaria ilaria ilaria -9- -9- -22- -22- 8. Cleaning and maintenance before performing any maintenance operations on the stove, adopt the following precautions: - check that all the parts of the stove are cold. - make sure that the ash is completely extinguished. - m...

  • Page 11

    Manual ilaria manual manual manual ilaria ilaria ilaria -10- -10- -21- -21- 7.5.3. Language the language can be selected from italian, german, french and english. To access the setting, select the lingua [set language] menu and use buttons p4 and p5 to select the desired language. 7.5.4. Stove statu...

  • Page 12

    Manual manual manual manual ilaria ilaria ilaria ilaria -11- 5.2. Installation 5.2.1. Stove gas exaust the gas exhaust system works due to the negative pressure in the combustion chamber and the slight positive pressure in the gas exhaust pipe. The gas exhaust system must therefore be airtight, usin...

  • Page 13

    Manual ilaria manual manual manual ilaria ilaria ilaria 3- unwind the room probe on the rear of the stove, making sure it doesn’t rest on hot surfaces. 4- correctly connect the pellet stove to the flue. 5- fill the hopper with pellets (diameter 6 mm). 6- open the door and check that the firepot is p...

  • Page 14

    Manual manual manual manual ilaria ilaria ilaria ilaria line neutral 230 vac exhaust fan screw m alf ald ignition heater transformer 5x20 “f“ 4a fuse hear t tr asformator cn3 cn1 cn7 cn4 cn6 cn8 cn9 ignition relay microprocessor n al1 al2 acc coc n.Pellet n.H 2 o n.Amb term tc col. Red col. Blue flu...

  • Page 15

    Manual ilaria manual manual manual ilaria ilaria ilaria 7.3.4. Economy phase (or flue gas modulation) the flue gas modulation phase occurs if the flue gas temperature reaches the maximum threshold of 250°c (parameter pr14) or the room temperature reaches the “set temperature”. During this phase, the...

  • Page 16

    Manual manual manual manual ilaria ilaria ilaria ilaria 7.3.1. Ignition phase the stove is started by pressing the on/off button for a few seconds. The procedure starts by activating the ignition heater and continuously filling the pellets using the screw. The display shows, in sequence, the message...