FAAC 424 D LS Instructions For Use Manual

Manual is about: 24 vdc electronic control unit for swing gates

Summary of 424 D LS

  • Page 1

    424 d ls istruzioni per l’uso - norme di installazione instructions for use - directions for installation instructions - regles d’installation instrucciones para el uso - normas para la instalacion gebrauchsanleitung - anweisungen zur installation gebruiksaanwijzingen – installatievoorschriften.

  • Page 2

    Avvertenze per l’installatore obblighi generali per la sicurezza 1) attenzione! È importante per la sicurezza delle persone seguire attentamente tutta l’istruzione. Una errata installazione o un errato uso del prodotto può portare a gravi danni alle persone. 2) leggere attentamente le istruzioni pri...

  • Page 3

    Del previsto. 7) no instalen el aparato en atmósfera explosiva: la presencia de gas o humos inflamables constituye un grave peligro para la seguridad. 8) los elementos constructivos mecánicos deben estar de acuerdo con lo estable- cido en las normas en 12604 y en 12605. Para los países no pertenecie...

  • Page 4: English

    12 english ce declaration of conformity notes on reading the instruction read this installation manual to the full before you begin installing the product. The symbol indicates notes that are important for the safety of persons and for the good condition of the automated system. The symbol draws you...

  • Page 5: English

    13 english 24 vdc electronic control unit for swing gates use instructions - installation instructions 1. General characteristics this 24 vdc control unit for swing gates offers high performance and a wide range of adjustments: opening and closing decelerations, possibility of managing one or two mo...

  • Page 6: English

    14 english 4. Connections and operation 4.1. Terminal board cn1 4.1.1. P ower supply 22v “ vac-vac ” terminals. The secondary circuit of the 24v~ 50/60 hz transformer should be connected to this input. Power supplied by the transformer is signalled by the lighting of the “ alim ” led located under t...

  • Page 7: English

    15 english 4.3. Terminal board cn3 4.3.1. M otor 1 closing limit - switch “ comf - fcc1 ” terminals. Normally closed contact. This is tripped and stops the closing motion of motor 1. The status of this input is signalled by led fcc1 . 4.3.2. M otor 1 opening limit - switch “ comf - fca1 ” terminals....

  • Page 8: English

    16 a2 english 4.4.5. O pening safety devices “ com - fsw op ”terminals. Normally closed contact. Connect, to these terminals, any safety device (e.G. Photocell, safety edge, pressure switch etc..) which, by opening a contact, affects the gate’s opening motion, causing it to stop immediately. When th...

  • Page 9: English

    17 english during normal operation, the display shows gate status. The displayed values are indicated on the following table: display value gate status - - gate at rest o p gate opening t c gate open in pause status (only with automatic re-closure enabled - see next paragraph) c l gate closing 9. Ad...

  • Page 10: English

    18 english display description deceleration point percentage: this parameter is used to set the length of the decelerated section, selecting from the two set values. H0 40% of maximum memory-stored opening h1 20% of maximum memory-stored opening speed during deceleration phase: this parameter is use...

  • Page 11: English

    19 english 12. Protection fuses fuse protection fuse protection fuse protection fuse protection f1 =t10a 250v - 5x20 power supply 24v~ f2 =t0.63a 250v - 5x20 supply to accessories and battery- charger f3 =r0.63a 250v - 5x20 flashing lamp output f4 =r3.15a 250v - 5x20 electric lock output 13. Connect...

  • Page 12: English

    20 english 14. Function l ogic s a utomatic ”a ” logic c=1 d=0 e=0 gate status pulses open a open b stop opening safety devicesopening safety devices closing safety devicesclosing safety devices op/cl safety device closed opens the leaf and r e- closes after pause time executes leaf partial opening ...

  • Page 13: English

    21 english semi-automatic ”e” logic c=0 d=0 e=0 gate status pulses open a open b stop opening safety devicesopening safety devices closing safety devicesclosing safety devices op/cl safety device closed opens the leaf executes partial opening no effect (open disabled)(open disabled) disables open co...

  • Page 14: English

    22 english 15. How to secure the board the outdoor enclosure is designed to house the control unit, the toroidal transformer and any buffer batteries (optional). To secure the toroidal transformer and the board support, consult the specific instruc- tions. To secure the control board, follow the ins...

  • Page 15

    Note - notes - note - notas - anmerkung - opmerkingen.

  • Page 16: Faac S.P.A.

    Le descrizioni e le illustrazioni del presente manuale non sono impegnative. La faac si riserva il diritto, lasciando inalterate le carat- teristiche essenziali dell’apparecchiatura, di apportare in qualunque momento e senza impegnarsi ad aggiornare la presente pub- blicazione, le modifiche che essa...