Semi-automatic ”E” logic C=0 d=0 E=0
Gate status
Pulses
Open A
Open B
Stop
Opening safety devicesOpening safety devices
Closing safety devicesClosing safety devices
OP/CL safety device
Closed
Opens the leaf
Executes partial opening
No effect
(OPEN disabled)(OPEN disabled)
Disables OPEN com-
mands
No effect
Disables OPEN com-
mands
Open
Closes
Closes the gate
No effect
(OPEN disabled)
No effect
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Closing
Reverses gate motion
No effect
Stops operation
No effect
Reverses gate motion
Stops operation and r
everses on r
elease
Opening
Reverses gate motion
No effect
Stops operation
Stops operation and resumes on r
elease
No effect
Stops operation and resumes on r
elease
Stepped Semi-automatic ”EP” logic C=0 d=1 E=0
Gate status
Pulses
Open A
Open B
Stop
Opening safety devicesOpening safety devices
Closing safety devicesClosing safety devices
OP/CL safety device
Closed
Opens the leaf
Executes partial opening
No effect
(OPEN disabled)(OPEN disabled)
Disables OPEN com-
mands
No effect
Disables OPEN com-
mands
Open
Closes
Closes the gate
No effect
(OPEN disabled)
No effect
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Closing
Stops gate operation
and opens on next pulse
No effect
Stops operation
No effect
Reverses gate motion
Stops operation and r
everses on r
elease
Opening
Stops gate operation
and opens on next pulse
No effect
Stops operation
Stops operation and resumes on r
elease
No effect
Stops operation and resumes on r
elease
Condo ”D” logic C=1 d=0 E=1
Gate status
Pulses
Open A
Open B
Stop
Opening safety devicesOpening safety devices
Closing safety devicesClosing safety devices
OP/CL safety device
Closed
Opens the leaf and r
e-
closes after pause time
Executes leaf partial opening and r
e-closes
after pause time
No effect
(OPEN disabled)
Disables OPEN com-
mands
No effect
Disables OPEN com-
mands
Open on pause
Reloads pause time
Closes the gate
immediately
Stops operation
No effect
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Disables OPEN com-
mand and, on r
elease,
re-closes after 5 sec..
Closing
Reverses gate motion
No effect
Stops operation
No effect
Reverses gate motion
Stops operation and r
everses on r
elease
Opening
No effect
No effect
Stops operation
Stops operation and resumes on r
elease
No effect
Stops operation and resumes on r
elease