FAAC 424 D LS Instructions For Use Manual - English
17
ENGLISH
During normal operation, the display shows gate status. The displayed values are indicated on the following table:
DISPLAY VALUE
GATE STATUS
- -
Gate at rest
O P
Gate opening
t c
Gate open in pause status (Only with automatic re-closure enabled - see next paragraph)
C L
Gate closing
9. ADJUSTING THE OPERATING PARAMETERS
Before you begin adjusting the operating parameters, select the type of operation for the control unit: with
or without encoder (see paragraph 6).
To access operating parameter adjustment, follow the instructions below:
1- When you have made all the necessary connections, power up the system and check if all the signalling LEDs are
in the situation specified in paragraph 7.
2- The display shows value “
--
”.
3- Press and hold down push-button
P2
until the display shows the name and value of the first parameter.
4- Press push-button
P1
to change the value of the parameter.
5- To move on to the next parameter, press push-button
P2
.
6- When 60 seconds have elapsed without any key being touched, the control unit exits the adjustment mode. You can
manually exit the adjustment mode by scrolling all the parameters with push-button
P2
. When the display shows
value “
--
“, you have returned to normal operation.
The following table summarises all settable parameters and the assignable values.
DISPLAY
DESCRIPTION
Adjusting the sensitivity of the electronic clutch
A1
Minimum motor force
A2
Medium-low motor force
A3
Medium-high motor force
A4
High motor force
Leaf 2 delay:
this parameter enables you to select the offset time of the two leaves.
b1
1.5 seconds offset
b2
3 seconds offset
b3
6 seconds offset
b4
10 seconds offset
Automatic Reclosure:
this function enables or disables automatic gate reclosure.
c0
Disabled
c1
Enabled
Operation of OPEN A command:
this function determines the behaviour of the OPEN A (total opening)push-button.
d0
Opens / Closes / Opens.....
d1
Opens / Stops/ Closes / Stops / Opens......
Condo function:
if this function is enabled while the gate is being opened, the start command is inhibited.
E0
Disabled
E1
Enabled
Over pushing stroke:
if you enable this function, at every OPEN pulse, the leaf on which the electric lock is installed starts
its closing movement for a few seconds. This facilitates release of the electric lock.
its closing movement for a few seconds. This facilitates release of the electric lock.
its closing movement for a few seconds. This facilitates release of the electric lock.
F0
Disabled
F1
Enabled
Courtesy light/ Flashing lamp:
with this parameter, you can select the type of output from the LAMP - LAMP terminals,
selecting from among flashing lamp and courtesy light.
selecting from among flashing lamp and courtesy light.
selecting from among flashing lamp and courtesy light.
G0
Flashing lamp
G1
Courtesy light (active for 90 seconds)