Faroudja DVP3000 Installation And Operation Manual - page 13
12
Then adjust the Values by pressing the
buttons. For direct access, press the COLOR
button, then enter the value on the keypad such
as 150.
Tint can be accessed by pressing:
Then adjust the Values by pressing the
buttons. For direct access, press the TINT
button, then enter the value on the keypad such
as 150.
Detail can be accessed by pressing:
Then adjust the Values by pressing the
buttons. For direct access, press the DETAIL
button, then enter the value on the keypad such
as 7.
Noise Reduction can be accessed by pressing:
Then adjust the Values by pressing the
buttons. For direct access, press the N. R.
button, then enter the value on the keypad such
as 5
Adjusting Detail
The Detail and Noise Reduction settings have
been optimized for most sources. However, the
viewers tastes and the types of software used
may require making adjustments of these
settings to fine tune the image. Theses controls
are very effective to either increase detail or to
help clean up poor quality video material. It is
recommended that adjustments be made in small
increments until the desired results are achieved.
It is important to not use too much Detail as the
image will start to look artificial.
RS232 Control
Connector: DB-9 Female
Baud rate: 9600 default, 8 bit,
1 stop bit and No Parity
(Adjustable 4800, 9600, 19,200)
Pin Configuration:
Pin 5 = Ground
Pin 3 = Rx
Pin 2 = Tx
All commands to the DVP3000 are sent using
ASCII text strings.
Note: A command must start with
the string header DVP3000 or
DVP3000U.
Following the header, a comma is used to delimit
the header from the command. All the
commands with their descriptions will be listed
below. All the text strings are terminated with a
carriage return (0x13). The header and command
are not case sensitive.
Since the picture settings are Input specific, the
input to be used, i.e. Video, Y/C or YPrPb, must
be selected first before adjusting and storing
settings.
EXAMPLE:
DVP3000,x,b128,C175,K128,N10,d6 (0x13
or cr)
TINT
M PIP
N.R.
PAU
DETAIL
STOP
RS232 Instructions