Fastech Ezi-servo plus-R User Manual - page 12
- 12 -
The user can set and save parameter values related to motion control by each drive module.
‘Value’ column displays the value applied to control current motion and can be edited.
3.1 Slave No
To display drive number for the current parameter list window. By using right/left arrow
key, the user can select other drive.
Buttons at the bottom bar including ‘SAVE to ROM’ are available only for the current drive.
To control several drive parameters, the user should execute related slave each by each.
3.2 Parameter Input
Select parameters as shown at the table, and the input box will be displayed and then the
user can edit parameter values. When the user inputs the parameter value, it is saved to
RAM area of the drive. The machine operates as the parameter is edited. However, when the
drive is powered off, the value is deleted. To continuously operate the machine as the
parameter value is set, the user must click ‘SAVE to ROM’ button and save the edited value
to ROM.
When the input value is out of right range, it is displayed in red. The value is not inputted
in RAM of the drive.
3.3 Parameter List Window Buttons
Click each button, and the following functions will be executed.
Button
Description
SET to DEFAULT
Converts all parameter values into ‘Default Value’.
LOAD ROM
Converts ‘Value’ items into values saved to the ROM area.
SAVE to ROM
Saves ‘Value’ items to the ROM area.
(Even though the drive is powered off, they are not deleted.)
LOAD FILE
Sets ‘Value’ items to the values saved to an external file.
SAVE to FILE
Saves the current values to an external file.
(The user defines folder position and file name. The
extension is *.fpt.)
For more information of parameter types and their functions,
refer to
「
User Manual–Text,
12. Parameters
」
.