Feller RC 101 User Manual - page 9
8
3
LCD display shows
“C1”,“C2”,“C3” or “C4”
1.
Master temperature controller is
short or broken
2.
Thermal resistor of the upper
cover is short or broken
3.
Master circuit board is damaged
4.
Power circuit board damaged
Send to the designated ser-
vice department for repair.
4
Rice is crude or time
of cooking is too long
1.
Time of thermal insulation is
insufficient
2.
Electric hot tray is deformed
3.
Inner pot is declined and
one side is hanging in the air
4.
There is foreign matter be-
tween the inner pot and elec-
tric hot tray
5.
Inner pot is deformed
6.
Master circuit board is damaged
7.
Surface of master tempera-
ture controller is stained.
1.
Keep war according to re-
quired conditions
2.
Fine sand paper can be used
for correcting slight deforma-
tion but the severe deformed
one should be Send to the
maintenance department for
replacement
3.
Turn the inner pot lightly to
make it return to normal
4.
Clean it up with 320# sand
paper
5.
Send to the designated ser-
vice department for a new
inner pot
6.
Send to the designated ser-
vice department for repair
7.
Clean it up with 320# sand
paper
5
Cook rice burnt or cannot
keep warm automatically
1.
Master circuit board is dam-
aged
2.
Surface of master tempera-
ture controller is stained
1.
Send to the designated ser-
vice department for repair.
2.
Clean it up with 320# sand
paper
6
Overflow happens when
making porridge
1.
Master circuit board is dam-
aged
2.
There is foreign object in the
steam valve
1.
Send to the designated ser-
vice department for repair.
2.
Clean the steam valve
7
Rice or porridge does not
boil within a long time
1.
Master circuit board is dam-
aged
2.
Temperature controller of
upper cover is abnormal
Send to the designated ser-
vice department for repair.