G-Force G6 Instruction Manual - page 10
16
17
LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM
Charged
capacity
Number
of
cells
Charging
time
Charging
current
Battery
voltage
screen. If both numbers are identical you can
start charging by press Start/Enter button. If
not, press Batt Type/Stop button to go back to
previous screen to carefully check the number
of cells of the battery pack before going ahead.
This screen shows the real-time status during
charge process. Press Batt Type/Stop key once
to stop the charge process.
‘FAST' CHARGING OF LITHIUM BATTERY
The charging current is getting smaller as the process goes to the near end
term of Lithium battery charging. To finish charging process earlier, this
program eliminate certain term of CV process. Actually, the charging current
will goes to 1/5 from the initial value to end the process while the normal
charging goes to 1/10 during CV term. The charging capacity may be a bit
smaller than normal charging but the process time will be reduced.
The value on the left side of the second lines
sets the charge current. The value on the right
side of the second lines sets the battery pack's
voltage. After setting current and voltage, press
Star/Enter for more than 3 seconds to start the
process.
This displays the number of cells you set up
and the processor detects. s detected by the
charger and cells set by you at the previous
screen. If both numbers are identical you can
start charging by press Start/Enter button. If
LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM
Start
Enter
Current
voltage
battery
Supplied
capacity
Charge
current
Charging
time
Number
of
cells
not, press Batt Type/Stop button to go back to
previous screen to carefully check the number
of cells of the battery pack before going ahead.
This screen shows the real-time status during
charge process. Press Batt Type/Stop key once
to stop the charge process.
'STORAGE' CONTROL OF LITHIUM BATTERY
This is for charging or discharging Lithium battery not to be used for the
time being. The program will determine to charge or discharge the battery to
the certain voltage depending on the voltage of the battery at its initial
stage. They are different from the type of the battery, 3.75V for LiIo, 3.85V
for LiPo and 3.3V for LiFe per cell. If the voltage of battery at its initial stage
is over the voltage level to storage, the program will start to discharge.
At this screen, you can set up the current and
voltage of the battery pack. Charging and
discharging will make the batteries come to the
voltage level of storage state.
This displays the number of cells you set up
and the processor detects. s detected by the
charger and cells set by you at the previous
screen. If both numbers are identical you can
start charging by press Start/Enter button. If
not, press Batt Type/Stop button to go back to
previous screen to carefully check the number
of cells of the battery pack before going ahead.
Start
Enter
Batt type
Stop
'> 3 seconds
'
Start
Enter
Start
Enter
Batt type
Stop
'> 3 seconds '
- +
- +
- +
- +