30
31
It incorporates a variety of functions for the systems to verify processes
and the state of the electronics. In case of an error the screen will
display the cause of error and emit an audible sound.
Incorrect polarity connected.
The battery is interrupted.
CONNECT ERROR
CHECK MAIN PORT
The Battery connection is wrong.
The cell number is wrong.
CELL NUMBER
INCORRECT
Voltage of one cell in the battery pack is too high.
CELL ERROR
HIGH VOLTAGE
Voltage of one cell in the battery pack is too low.
CELL ERROR
LOW VOLTAGE
The internal temperature of the unit goes too high.
INT.TEMP.TOO HI
DC IN TOO LOW
Input voltage less than 11V.
Input voltage higher than 18V.
DC IN TOO HIGH
BATTERY WAS FULL
The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.
WARNING AND ERROR MESSAGE
CELL ERROR
VOLTAGE-INVALID
Voltage of one cell in the battery pack is invalid.
The external temperature of the unit goes too high.
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
The battery capacity is more than the maximum
capacity which the user sets.
OVER TIME LIMIT
The charging time is longer than the maximum
charging time which the user sets.
BALANCE CONNECT
ERROR
The balance connect is wrong.
SPECIFICATION
SPECIFICATION
(stated values refer to one charger except built-in power supply, dimension & weight)
DC Input
Charge circuit power
Charge current range
Discharge current range
Current drain for balancing port
NiCd/NiMH battery cell count
LiPo/LiFe/Lilon cell count
Pb battery voltage
Net weight
Dimension
11-18Volt
DC
80W
Input
0.1-10.0A
10W
0.1-2.0A
200mA/cell
1-15Cells
1-6Cells
2-20V
300g
138.5x80.5x28.5mm
Discharge current power
THE SET CONTAINS
1. G-force G6 Charger
2. Plug-in battery clamps
3. XT60 DC Cable
4. Dean connector with
banana plug cable
5. Tamiya charging cable
6. Futaba RX charging cable
7. 3pin XH-TP/FP adaptor cable
1
2
3
4
5
6
7