BATTERY MEMORY SET
The charger can store up to 10 different charge/discharge profiles for your
convenience, and the stored profiles can be recalled quickly without having
to go through the setup process.
BATT MEMORY
【1】
ENTER SET
BATT TYPE
LiPo
Enter the battery memory program, you can change
the battery type(Lipo, Lilo, LiFe, NiMH, NiCd, Pb
battery), voltage, charge current by pressing the
Start/Enter button to make the value blink, the or
+ buttons to change the value, and Start/Enter
button once more to store the value and move to the
next value or screen. (Note: The battery used for this
example is a 2S(7.4V) Lipo battery.
DSCH CURRENT
2.2A
BATT VOLTS
7.4V(2S)
CHARGE CURRENT
4.9A
DSCH VOLTAGE
3.0V/CELL
Set the discharge current, which can be adjusted
(0.1A-2.0A).
Set the discharge voltage, which can be adjusted
(3.0V/CELL-3.3V/CELL).
Set the voltage and number of cells, along with the
normal voltage (1-6S).
Set the charge current, which can be adjusted(0.1-
10.0A).
TVC=YOUR RISK
4.20V
SAVE PROGRAM
SAVE
SAVE PROGRAM
ENTER
BATT MEMORY
【1】
LiPo 7.4V(2S)
BATT MEMORY
【1】
C:4.9A D:2.2A
ENTER CHARGER
LOAD……
next flash
TEMPERATURE
CUT-OFF 50C
Set the terminal voltage, which can be adjusted
(4.18-4.30V).
Save the program set by pressing the Start/Enter
button for more than three seconds.
This screen indicate the saved profile.
This screen indicates that the charge profile is being
loaded.
Once you've saved a charge profile, you can load
those settings to use later. To load a memory, you
have to press the Start/Enter Button for more than 3
seconds. Otherwise you only enter the setting mode.
BATTERY MEMORY SET
Set the cut-off temperature, which can be
adjusted(20 C/68 F-80 C/176 F).
Start
Enter
'> 3 seconds '
Start
Enter
'> 3 seconds
'
- +
- +
- +
- +
- +
- +