Gabarron electric boilers do not require any special maintenance for a prolonged and trouble-free life however the
following points should be observed:
-Check and maintain the heating system pressure between 1 & 1.5 bar when cold. Frequent re-filling of the system could
cause scaling and corrosion and should be avoided. Regular pressure loss could indicate a leak and should be investigated
promptly.
CAUTION – Under no circumstances should the boiler be switched on when the system is dry..
CAUTION - Never start the boiler when the DHW tank is empty; to fill it for the first time open a hot water
tap and wait until water comes out of it.
-Keep the ventilation openings on the boiler clear to ensure correct operation and protect from overheating. Do not
place or store objects on the boiler.
-Protect against freezing by ensuring power is maintained to the boiler at all times unless the water supply is interrupted
or the heating system is empty. In dwellings frequently un-occupied or at risk of freezing an appropriate anti-freeze can
be added to the heating system at a concentration of not more than 30% by volume. Otherwise it is recommended to
isolate the power and completely drain the heating and hot water systems.
- The outer case can be cleaned with a damp cloth having first isolated the boiler from the mains. Do not use solvents or
abrasive cleaners.
10 ENVIRONMENTALINFORMATION
Gabarron boilers are manufactured within a certified environmental management system. From the design stage, all the
production phases are performed taking into account the most rigorous environmental requirements. For example, the
selection of materials involves guaranteeing their biodegradability, re-use and recycling.
When this boiler’s long, useful life is over; it must be handed in to an electrical equipment collection point for proper
recycling. By ensuring that this product is correctly disposed of, you will help to avoid any possible negative effects on
the environment and public health that could occur if this product is not properly handled. To obtain more detailed
information on the recycling of this product, contact your local authority, your waste disposal service or the shop where
you purchased the product.
These regulations only apply in EU member countries.
Heating expansion vessel 6L
ref. 60091510
DHW. expansion vessel 2L
ref. 60091515
DHW. expansion vessel hose CMX
ref. 60100020
50 L DHW. insulated tank
ref. 60100072
Insulated heating header tank
ref. 60101700
Circulation pump 25-40 (130)
ref. 60190070
Circulation pump 25-60 (130)
ref. 60190071
Main electronic card with support
ref. 60101310
DHW. electronic card with support
ref. 60101320
Controls card CM15 & CM18
ref. 60100510
Controls card CMX15 & CMX18
ref. 60100540
Temperature probe, white connector
ref. 60100580
Temperature probe, black connector
ref. 60100590
15 kW heating resistance & joint 140
ref. 60100750
18 kW heating resistance & joint 140
ref. 60100760
15 kW DHW. resistance & joint
ref. 60100700
DHW. resistance joint
ref. 60100068
¾” heating flow detector
ref. 60100800
0-4 bar pressure gauge
ref. 60100820
100°C thermal limiter
ref. 60091140
80°C thermal limiter
ref. 60091150
Automatic purge
ref. 60091280
3 bar central heating relief valve
ref. 60100840
7 bar DHW. relief valve
ref. 60100850
DHW. retention valve
ref. 60100830
½” filling / shut off valve
ref. 60091160
Adhesive controls cover 220x60
ref. 60100502
Adhesive controls cover 140x50
ref. 60100508