11 TECHNICAL DATA
CMX15
CM15
Frequency
Hz
50
50
Connection 3x400V+N~
¿
¿
Output limited to 15kW; Maximum intensity
A
21.7
21.7
Output limited to 13kW; Maximum intensity
A
21.7
21.7
Output limited to 12kW; Maximum intensity
A
21.7
21.7
Output limited to 11kW; Maximum intensity
A
21.7
21.7
Output limited to 10kW; Maximum intensity
A
21.7
21.7
Output limited to 9kW; Maximum intensity
A
13.0
13.0
Output limited to 8kW; Maximum intensity
A
13.0
13.0
Output limited to 7kW; Maximum intensity
A
13.0
13.0
Output limited to 6kW; Maximum intensity
A
13.0
13.0
Output limited to 5kW; Maximum intensity
A
13.0
13.0
Output limited to 4kW; Maximum intensity
A
13.0
13.0
Output limited to 3kW; Maximum intensity
A
13.0
13.0
Connection 230V~ single phase
¿
1
¿
1
Nominal maximum intensity 15kW
A
65.2
65.2
Maximum converted intensity at 13kW
A
56.5
56.5
Maximum converted intensity at 12kW
A
52.2
52.2
Maximum converted intensity at 11kW
A
47.8
47.8
Maximum converted intensity at 10kW
A
43.5
43.5
Maximum converted intensity at 9kW
A
39.1
39.1
Maximum converted intensity at 8kW
A
34.8
34.8
Maximum converted intensity at 7kW
A
30.4
30.4
Maximum converted intensity at 6kW
A
26.1
26.1
Maximum converted intensity at 5kW
A
21.7
21.7
Maximum converted intensity at 4kW
A
17.4
17.4
Maximum converted intensity at 3kW
A
13.0
13.0
DHW available time with 15kW
min
5’49”
-
DHW available time with 13kW
min
6’42”
-
DHW available time with 12kW
min
7’16”
-
DHW available time with 11kW
min
7’56”
-
DHW available time with 10kW
min
8’43”
-
DHW available time with 9kW
min
9’41”
-
DHW available time with 8kW
min
10’54”
-
DHW available time with 7kW
min
12’27”
-
DHW available time with 6kW
min
14’32”
-
DHW available time with 5kW
min
17’26”
-
DHW available time with 4kW
min
21’48”
-
DHW available time with 3kW
min
29’04”
-
DHW available time with 2kW
min
43’36”
-
Weight
kg
70
32
Insulated steel heater header
¿
¿
50 L stainless steel insulated DHW store
No CFC
¿
-
Stainless steel plated resistance elements INCOLOY800
DHW
¿
-
Stainless steel plated resistance elements INCOLOY800
Heating
¿
¿
6 litre expansion vessel
¿
¿
DHW 2 litre expansion vessel
¿
-
Electronic regulation of heater modulation
¿
¿
Electronic regulation DHW
¿
-
Digital display
¿
¿
0-4 bar
pressure gauge
¿
¿
Accelerator pump
¿
¿
Automatic purge
¿
¿
TRIACS silent power switches
¿
¿
Heating flow detector
¿
¿
100°C heating temperature limiter
¿
¿
80°C DHW temperature limiter
¿
-
3 bar
central heating relief valve
¿
¿
7 bar
DHW relief valve
¿
-
DHW retention valve
¿
-
Ambient thermostat intake
¿
¿
Anti-electrolysis DHW hoses.
¿
-
¿
included
1