Display
Function
Advance warning phase / external with options relay
not active
5 seconds
10 seconds
Options relay (accessories)
not active
Relay clocks during advance warning phase
and door travel
Relay is switched on during door travel and
advanced warning phase
Relay picks up with the operator lighting. It is
switched on during the advance warning phase
when parameters 1-5 have been activated in
menu 2.
Relay is switched on during door travel
Relay picks up for one second when travel
or advance warning phase has started
e.g. a wipe impulse to switch on automatic
staircase lighting with 100 % duty cycle
Maintenance indication
not active
active
Press the PRG button to return to normal operation
(menu 0).
7.6
MENU 6 – force limit during operation in the
CLOSE direction (see fig.
25
)
In this menu, the sensitivity of the automatic force limit for
the closing cycle can be set (factory setting: parameter 4).
Note
Increasing the force value (parameter greater than 4) is only
possible if parameter 3 has been selected in menu J.
ATTENTION
Do not select an excessively high setting as
excessive force may cause damage to equip-
ment or injuries to persons.
For doors moving easily, a low value can be selected
if the sensitivity to obstructions is to be increased.
Press the PRG button to return to normal operation
(menu 0).
7.6.1 Checking the forces in the CLOSE direction
When changing the settings of menu 6, the forces as
defined in EN 12453 in the CLOSE direction must be
complied with; i.e. a subsequent check is absolutely
essential.
7.7
MENU 7 – behaviour during operation in the
CLOSE direction (see fig.
26
)
In this menu, the automatic belt relief, the braking
behaviour and the speed in the CLOSE end-of-travel
position can be influenced.
Note
After the menu changes, a learning cycle may have to be
carried out.
Display
Function
Soft stop
long
short
Relief
automatic
short
Speed
slow
normal
Press the PRG button to return to normal operation
(menu 0).
7.8
MENU 8 – force limit during operation in the
OPEN direction (see fig.
27
)
In this menu, the sensitivity of the automatic force limit
for the opening cycle can be set (factory setting: para-
meter 4).
Note
Increasing the force value (parameter greater than 4) is only
possible if parameter 3 has been selected in menu J.
ATTENTION
Do not select an excessively high setting as
excessive force may cause damage to equip-
ment or injuries to persons.
For doors moving easily, a low value can be selected
when the sensitivity to obstructions is to be increased.
Press the PRG button to return to normal operation
(menu 0).
7.8.1 Checking the forces in the OPEN direction
When changing the settings in menu 8, the forces as
defined in EN 12453 in the OPEN direction must be
complied with, i.e. a subsequent check is absolutely
essential.