Goldine Controls Pro Logic PL-P-4 Installation Manual - Optional Base Station
AQL2-SS-RF, AQL2-POD
The AQL2-SS-RF and AQL2-POD are waterproof portable remote controls that are designed to be
used in and around the pool/spa area. These units float and can be left in the water for easy access.
Optional Base Station
The AQL2-BASE-RF optional base station must be installed if any wireless remote control is used. To
install the base station, remove the knockout on the upper left side of the Pro Logic main control unit, insert
the base station, and then tighten the nut from the inside. Also refer to the Base Station manual and the
diagram on page 19.
Optional Valve Actuators
For optional actuators used with the Pro Logic—note that the internal cams in the actuator may also have
to be adjusted depending on the way the actuator is mounted on the valve and the desired valve action.
8
23
Filter Operation
If “Spa Spillover” is selected, the Pro Logic will automatically switch the pool/spa suction
and return valves to “spillover” at the start of the programmed pool filtering time period or
when the super-chlorinate function is turned on. The valves will remain in this position for
the remainder of the super-chlorinate period. This option is usually preferable because both
the pool and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the Pro Logic will switch the pool/spa valves to the “pool
only” position at the start of the programmed pool filtering time period or when the super-
chlorinate function is turned on. This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is “Pool Only” or “Spa Only”. When enabled,
Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled (default), the return and suction pool/spa valves function normally.
Filter Off Valve Change
This menu appears only if Pool/Spa setup is set to “Pool and Spa - Std”. When enabled
(default), the filter pump will shut off for 35 seconds whenever the Pool/Spa valves are
turning. The pump will NOT shut off when a heater is in Heater Cooldown mode.
Filter Config.
+ to view/change
Filter Pump
1 Speed
Freeze Protect
Enabled
Lowest Speed
10%
Highest Speed
100%
Push to access pump options
Rotates between 1-speed (default), 2-speed and variable speed options
Toggle between Enabled (default) and Disabled Freeze Protection
Adjust the lowest speed desired for variable speed operation
Adjust the highest speed desired for variable speed operation
Move to next menu item
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to next menu item
if “Variable Speed” is selected
if “Variable Speed” is selected
Freeze Temp
38ºF
Freeze Protect
High Speed
Adjust the desired freeze protection temperature (33ºF - 42ºF)
Toggle between high speed (default) and low speed
Move to previous/next configuration menu
Move to next menu item
if “Freeze Protect” is enabled
if “Freeze Protect” is enabled
and “1-speed Filter” is not selected
Filter Pump
For 2-speed pumps: When a 2-speed pump is configured, one of the AUX relays must also
be configured to control the low speed motor winding on the pump. Refer to the appropriate
sections in the Installation manual for specific information regarding the control logic for 2-
speed and variable speed pump operation.
For the Hayward Tristar variable speed pump: The Filter relay is used to supply input power
to the VSC pump control. The relay will be on when the filter pump output is on. When the
filter pump output is off, the relay will be off. On , off and speed is controlled by commands
sent to the pump.
RETURN
SUCTION
OUT
(Common)
IN
(Common)
OUT
IN
OUT
IN