Before You Begin
What’s Included
Before attempting to install the Pro Logic system, check that the following components have been included
in the package:
Pro Logic Electronics Unit
(3) Temperature sensors with 15 ft. (5m) cable, hose clamp
What’s NOT Included
Some of the additional items that you may need to complete an installation include:
Circuit breakers
None are included with control—see page 12 and inside of door for suitable breakers
Wire
4-conductor cable (electronics unit to remote display/keypad)
Wire/conduit for 100A service from main panel to Pro Logic
Wire/conduit for filter pump and other high voltage loads
Wire for bonding
Miscellaneous
Utility electrical outlet and weatherproof cover (for mounting on side of Pro Logic)
Mounting hardware (screws, etc.) for mounting Pro Logic and remote display/keypad
Valves (use standard Hayward, Pentair/Compool, or Jandy valves)
Additional valve actuators
Accessory Products - Order Separately
AQL-CL
Chlorination kit
AQL-CL-25FT
Chlorination kit with 25ft cable
AQL-CHEM
ORP & pH sense kit
AQL-CHEM2
pH dispense kit
AQL-WW-P-4
Wired Wall Mount Remote Display
AQL-SS-6B-x (x=W/B)
Wired Spa Side 6 Function Remote Control, 150ft cable, specify color (white or black)
AQL2-POD
Handheld Wireless Waterproof Remote with Charging Station (AQL2-BASE-RF required)
AQL2-Tx-RF-P-4
Wireless Table Top remote (AQL2-BASE-RF required)
AQL2-SS-RF
Wireless Spa Side Remote Control (AQ2L-BASE-RF required)
AQL2-BASE-RF
Base Receiver
AQL-DIM
Light Dimmer Relay
GVA-24
Valve Actuator
V&A-xx
Valve & Actuator (xx=1P (1.5” pos. seal), -2P (2” pos. seal)
1
30
All Timeclocks
7-day
Move to previous/next configuration menu
Toggle between 7-day (default) and Weekend/Weekday time options
This selection affects ALL of the timeclock logic in the Pro Logic. If “7-day” is selected, each
timeclock will have one set of turn-on/turn-off settings that operate every day of the week. If
“Weekend/Weekdays” option is selected then the user can enter one set of turn-on/turn-off
times for the weekend (fixed as Saturday/Sunday) and another set of turn-on/turn-off times
for weekdays (Monday through Friday).
Time Format
12 hour AM/PM
Units
ºF and PPM
Move to previous/next configuration menu
Move to previous/next configuration menu
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options
Reset Config. to
Default Press +
Are you sure?
+ to proceed
Config. reset
Confirmed
Initiate reset of all configuration parameters
Reset all configuration parameters
Move to previous/next configuration menu (config. not reset)
Move to previous/next menu (config. not reset)
Move to previous/next configuration menu
Use this function to erase all previous system configuration and reset all configuration
parameters back to the factory default values. This function is NOT reversible--be careful.
6. System Startup and Checkout
Before Startup
Before starting the Pro Logic for the first time, be sure that the following items have been completed:
1. Pool/spa chemicals are within the recommended levels according to the chart on page 3.
2. Pool/spa salt level is between 2700 – 3400 PPM.
3. Properly rated circuit breakers are installed in the Pro Logic subpanel.
4. All wiring is performed according to NEC and local codes.
5. The Pro Logic is properly grounded and bonded.
6. The Pro Logic is properly configured to control all desired functions.
Program Automatic Operation
Refer to the programming flow chart on the back cover of this manual for a listing of the available menus
and the items included in each menu.
Settings Menu
Heater and/or solar thermostat settings
Chlorinator settings
Day and Time
Timers Menu
Timeclock and/or Countdown timer settings