    User manu al cod. 50121878 t632 gb2 en rev.0315 video door entry system 2 wires installation gb2 nexa modular.

  • Page 2

    Video door entry system gb2 nexa modular - building introduction first of all we would like to thank and congratulate you for the purchase of this product. The commitment to reach the satisfaction of our customers is stated through the iso-9001 certification and for the manufacturing of products lik...

  • Page 3

    Video door entry system gb2 nexa modular - building characteristics - video door entry system with simplified installation (2 wire bus without polarity). - up to 4 access door panel (necessary dp-gb2 distributor for more than 1 door panel access) per installation. - up to 20 monitors and apartments ...

  • Page 4

    Video door entry system gb2 nexa modular - building door panel description (nexa modular) 4 sound module el632/gb2 push buttons electronic module el610d short connection cable, it is supplied with el610d module (16 cm length). , for 5 single push buttons or 10 double push buttons. , on video systems...

  • Page 5

    Video door entry system gb2 nexa modular - building sound module description (el632/gb2) 5 microphone. Speaker. Front side. Sound module push buttons (x2). Installation terminals (gb2 bus). Push buttons connector. Back side. : positive, ground (12vdc output for golmar 12vdc lock release). : "c" cont...

  • Page 6

    Video door entry system gb2 nexa modular - building push buttons module description (el610d) 6 front side. Push buttons module (x10). Configuration dip switch (push buttons call code). Push button number. Input / output push buttons connector (x3). Back side. Push buttons module description (el610d)...

  • Page 7

    Video door entry system gb2 nexa modular - building door panel installation 7 1 ncev90cs 99 135,5 40 modules model w h d 2 ncev90c 99 238 56 3 cev90 99 mm. 328 mm. 56 mm. Break the bottom flange to pass the cables through. In case of door panels with more than one embedding box, break the side flang...

  • Page 8

    Video door entry system gb2 nexa modular - building 8 pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes. Insert the sound module in the t...

  • Page 9

    Video door entry system gb2 nexa modular - building 9 hold the frame on the embedding box: insert the hinge that it is supplied with the product in the embedding box, as shown in the drawing. To hold the frame on the embedding box, insert the hinge in the housings arranged for this purpose in the fr...

  • Page 10

    Video door entry system gb2 nexa modular - building 10 plug the push buttons with the connection cable rap-610d: the push buttons module el610d must be configured, to assign a call code to the push buttons. Make this configuration with the dip switch placed in the back side of the module. Depending ...

  • Page 11

    Video door entry system gb2 nexa modular - building 11 double push button module coding: 1 2 3 4 5 6 on na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relé 2 relé 1 _ 12vdc 1 2 3 4 5 6 7 8 on 1 2 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 el632...

  • Page 12

    Video door entry system gb2 nexa modular - building 12 1 2 3 4 5 6 on na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relé 2 relé 1 _ 12vdc 1 2 3 4 5 6 7 8 on 1 2 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 el632/gb2 el610d code 0 code 5 code 4 c...

  • Page 13

    Video door entry system gb2 nexa modular - building 13 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 code 25 code 24 code 23 code 22 code 21 code 30 code 29 code 28 code 27 code 26 code 31 coming from previous page. 1 2 3 4 5 ...

  • Page 14

    Video door entry system gb2 nexa modular - building 14 configuration dip switch of the sound module (el632/gb2): 1 2 3 4 5 6 on + c1 _ 1 the configuration dip switch is located on the left side of the rear part of the module. 1 2 3 4 5 6 on door panel address: dip switches: 1 and 2 off (address 1), 1...

  • Page 15

    Video door entry system gb2 nexa modular - building 15 description of the vocal synthesis (audible indications from the door panel): audible indications from the door panel for people with impaired vision. If the vocal synthesis in the sound module is activated (see pages 14 and 16 to congure), a v...

  • Page 16

    Video door entry system gb2 nexa modular - building 16 once finished the works of wiring, configuration and adjustments, fix the frame in the embedding box with the supplied screws. Close the frame: important: before closing the door panel(s), make a test call to any apartment to ensure that it work...

  • Page 17

    Video door entry system gb2 nexa modular - building 17 door panel assembly: insert a header in the lateral rods (at the bottom part) and fix it with the supplied screws (step 1 ), then insert the module (step 2 ). If the door panel is more than one module insert first the lower module, see picture a...

  • Page 18

    Video door entry system gb2 nexa modular - building 18 double door panel assembly: assembly the door panel a (step 1 ), as it is described in page 17 "door panel assembly”. Bear in mind that the rod that will join the door panel a and the door panel b have to be of the type door panel une rod, see p...

  • Page 19

    Video door entry system gb2 nexa modular - building 19 close the door panel: fix the door panel in the embedding box with the supplied screws. Door panel: double door panel: finish the door panel assembly by placing the closing heads, put the head on one side and then make a slight pressure on the o...

  • Page 20

    Video door entry system gb2 nexa modular - building 20 installing the fa-gb2 power supply: m 4 x 8 3,5 x 25 din-7972 din-963 replace the protection cover once the input terminals have been wired. It's recommended to protect the power supply by using a thermo-magnetic circuit breaker. Mount the din r...

  • Page 21

    Video door entry system gb2 nexa modular - building installation diagrams video installation with 20 vesta monitors, 5 dp-gb2 distributors and golmar 12vd.C lock release: 21 configuring the end of line in the last monitor. Dip 6 to on. Access door panel ** lock release max. 12 vdc/270ma. N n l n.A c...

  • Page 22

    Video door entry system gb2 nexa modular - building video installation with 20 vesta monitors, 10 d2l-gb2 distributors and golmar 12vd.C lock release: 22 configuring the end of line in the last monitor. Dip 6 to on. Access door panel ** na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relé 2 relé 1 _ 12...

  • Page 23

    23 bus bus bus bus thera bus bus bus code 3 code 2 code 1 code 0 code 14 code 13 code 12 ** ** ** ** ** ** ** thera thera thera thera thera thera video door entry system gb2 nexa modular - building installation diagrams video installation with 15 thera monitors, 4 dp-gb2 distributors and golmar 12vd...

  • Page 24

    Bus bus code 3 code 2 ** ** bus bus code 1 code 0 ** ** distances and sections: fa-gb2 d2l-gb2 a c b c d thera thera thera thera thera thera 24 video door entry system gb2 nexa modular - building video installation with 15 thera monitors, 8 d2l-gb2 distributors and golmar 12vd.C lock release: instal...

  • Page 25

    Video door entry system gb2 nexa modular - building 25 bus bus bus bus d c b a dp-gb2 end of line off ap ap access door panel 2 on 1 2 3 4 5 6 sw1 access door panel 1 on 1 2 3 4 5 6 sw1 ap ap access door panel 3 on 1 2 3 4 5 6 sw1 access door panel 4 on 1 2 3 4 5 6 sw1 n n l n.A cn1 cn2 internal rel...

  • Page 26

    Video door entry system gb2 nexa modular - building 26 access door panel on 1 2 3 4 5 6 sw1 na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relé 2 relé 1 _ 12vdc ap1 access door panel on 1 2 3 4 5 6 sw1 na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relé 2 relé 1 _ 12vdc connexion of 2 d.C locks release ...

  • Page 27

    Video door entry system gb2 nexa modular - building 27 notes:.

  • Page 28

    Golmar@golmar.Es www.Golmar.Es sistemas de comunicación s.A. Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis . Golmar reserves the right to make any modifications without prior notice..