Golmar GB2 Nexa Modular User Manual

Other manuals for GB2 Nexa Modular: User manual, User Manual, User Manual, User Manual, User Manual
Manual is about: Audio and Video Door Entry System, 2-Wire

Summary of GB2 Nexa Modular

  • Page 1

    User manu al code 50121981 t g en 632 b2a rev.0 1 2 7 audio and video door entry system nexa modular gb2 2-wire technology.

  • Page 2

    Nexa modular gb2 audio and video door entry system - building introduction first and foremost we would like to thank you for purchasing this product. Our commitment to achieving the satisfaction of customers like you is manifested through our iso-9001 certification and the manufacture of products li...

  • Page 3

    Characteristics - audio and video door entry system with simplified wiring (non-polarised 2-wire bus). - up to 4 access panels (dp-gb2a distributor required for more than one access panel) per installation. - up to 23 monitors and apartments with a vesta2 monitor per installation. (mixed installatio...

  • Page 4

    Description of the nexa modular door panel 4 sound module el632/gb2a el642/gb2a button module el610d short connection cable supplied with the el610a module (length 16 cm). , for 5 individual or 10 double buttons. , in video door entry systems with colour television camera. , in audio door entry syst...

  • Page 5

    Description of the el632 gb2a/el642 gb2a sound module 5 microphone. Speaker. Front. Sound module buttons (x2). Connector (gb2 bus). C el610d button module connector or n3301/gb2 keypad access control module . Back. : positive, negative (12vdc output for golmar dc electric lock). : contact “c” for el...

  • Page 6

    Description of the el610d button module 6 front. Module buttons (x10). Dip switch (button call code). Button number. Button connector input/output (x3). Back. Description of the el610d button module: nexa modular gb2 audio and video door entry system - building.

  • Page 7

    Installation of the door panel 7 1 n v s ce 90c 99 135,5 40 m dul s o e model w (width) h (height) d (depth) 2 cev90c n 99 238 56 3 cev90 99 mm. 328 mm. 56 mm. Break through the hole to allow entry of cables through the bottom part of the embedding box. In the case of door panels with more than one ...

  • Page 8

    8 pass the cable through the hole made in the embedding box. Embed the box and ensure that it is level and flush. Once the embedding box is positioned, remove the protective stickers from the door panel's fixing holes. Insert the sound module into the top of the frame module. Line up the clips on th...

  • Page 9

    9 installation of the door panel fastening the frame to the embedding box: insert the spring hinge which attaches to the product in the embedding box, as shown in the drawing. To fasten the frame to the embedding box, insert the spring hinge into the housings provided for this purpose in the frame, ...

  • Page 10

    10 installation of the door panel connecting the buttons to the rap-610d short connection cable: the el610d button module needs to be configured in order to assign a call code to the buttons. Carry out this configuration with the dip switch located at the back of the module. Depending on the configu...

  • Page 11

    11 installation of the door panel configuring double button module codes: el632 gb2a p1 p2 p2 nexa modular gb2 audio and video door entry system - building 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 el610d 1 2 3 on dip 4 5 ...

  • Page 12

    - in door panel systems with call pushbuttons, the first address on the monitor is 'code 0'. - in coded panel systems (n3301/gb2), 'code 0' is 'code 32', which means that when a call is made to a monitor with 'code 0' (dip 1 to dip 5 set to off), it needs to be entered on the n3301/gb2 numeric keypa...

  • Page 13

    13 installation of the door panel 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used continued f...

  • Page 14

    14 installation of the door panel nexa modular gb2 audio and video door entry system - building the el610d button module needs to be configured in order to assign a call code to the buttons. Carry out this configuration with the dip switch located at the back of the module. Depending on the configur...

  • Page 15

    Important: select a different configuration option for each el610d module. P1- p10: button 1 - button 10. (1) * ( ) factory setting. El610d button module module configuration option dip switch button code 2 dip1 1 4 6 3 5 7 dip2 dip3 dip4 dip5 dip6 dip7 dip8 p1 1 11 21 31 6 16 26 on off off off off ...

  • Page 16

    - in door panel systems with call pushbuttons, the first address on the is 'code 0'. Telephone - in coded panel systems (n3301/gb2), 'code 0' is 'code 128', which means that when a call is made to a with 'code 0' (dip 1 to dip telephone 7 set to off), it needs to be entered on the n3301/gb2 numeric ...

  • Page 17

    Continued from previous page. Continued overleaf 17 installation of the door panel nexa modular gb2 audio and video door entry system - building i mportant: the t562/tnhea telephone's dip 10 should be set to on. 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 ...

  • Page 18

    1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 continued from previous page. 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 continued overleaf 18 installation of the door panel nexa modular gb2 audio and video door entry system - buil...

  • Page 19

    1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 not used not used continued from previous page. 19 installation of the door panel nexa modular gb2 audio and video door entry system - building important: the t562/tnhea telephone's dip 10 should be set to on. El610d 1 2...

  • Page 20

    - in door panel systems with call push buttons, the first address on the is 'code 0'. Telephone - in coded panel systems (n3301/gb2), 'code 0' is 'code 128', which means that when a call is made to a with 'code 0' (dip 1 to dip telephone 7 set to off), it needs to be entered on the n3301/gb2 numeric...

  • Page 21

    21 installation of the door panel 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used continued f...

  • Page 22

    22 installation of the door panel 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 continued from previous page. 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 nexa modular gb2 audio and video door entry system - building continued over...

  • Page 23

    23 installation of the door panel 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 continued from previous page. 1 2 3 4 5 6 7 8 on 9 10 7 8 5 6 3 4 1 2 nexa modular gb2 audio and video door entry system - building important: the t562/tnhea telephone's dip 10 should be...

  • Page 24

    24 installation of the door panel description of the sound module dip switch: 1 2 3 4 5 6 on + c1 _ 1 the dip switch is located on the left side of the back of the module. 1 2 3 4 5 6 on door panel address: dip switches: 1 and 2 off (address 1), 1 on and 2 off (address 2), 1 off and 2 on (address 3)...

  • Page 25

    25 installation of the door panel description of the vocal synthesis (audible signals on the door panel): audible signals on the door panel for people with impaired vision. If vocal synthesis is enabled on the sound module (see page 24-25 for configuration), the following voice messages can be heard...

  • Page 26

    - then continue pressing to increase the vocal synthesis volume and the blink speed of led . There are 5 volume settings and the blink speed of led will increase for each. Slow to fast blink - low to high volume. After reaching “setting 5”, that is, maximum blink speed and volume, the next setting i...

  • Page 27

    27 installation of the door panel nexa modular gb2 audio and video door entry system - building once the wiring and configuration work is done, fix the frame to the embedding box using the screws supplied. Closing the frame: important: before closing the door panel(s) make a test call to any apartme...

  • Page 28

    28 installation of the door panel mounting the modules of a door panel: insert a clip-on cover into the side profiles (from the bottom) and fix it using the screws specified (step 1 ) and then insert the module (step 2 ). If the door panel has more than one module, insert the lower module first, see...

  • Page 29

    29 installation of the door panel mounting the modules of a double door panel: mount door panel a (step 1 ) as described in 'mounting the modules of a door panel' (see page 28), taking into account that the bar connecting panel a and panel b must be a door panel une rod, see drawing below. Insert a ...

  • Page 30

    30 installation of the door panel closing the door panel: fix the door panel to the embedding box using the screws supplied. Single door panel: double door panel: to complete the fitting of the panel, attach the clip-on covers by positioning one end and then applying slight pressure to the other end...

  • Page 31

    31 installation of the power supply unit installing the fa-gb2/a power supply unit: replace the protective cover once the input terminals have been wired. Please note that current regulations stipulate that the power supply must be protected by a circuit breaker. Connect the fa-gb2/a power supply un...

  • Page 32

    Wiring diagrams: video door entry system with 23 vesta2 monitors, 6 dp-gb2a distributors and golmar d.C. Lock release. 32 configure the end of line in the last monitor. Dip 6 to on. Access panel lock release max. 12 vdc/270ma. Bus bus bus bus bus bus bus bus d c b a dp- 2 gb a bus bus bus end of lin...

  • Page 33

    Wiring diagrams: video door entry system with 23 vesta2 monitors, 12 d2l-gb2 distributors and golmar d.C. Lock release. 33 configure the end of line in the last monitor . Dip 6 to on. Bus bus bus bus d2 d1 d2l- 2 gb bus bus bus bus bus bus d2 d1 d2l- gb2 bus end of line on apartment 4 apartment 3 re...

  • Page 34

    Mixed installation: up to 23 elements (vesta2 monitors/t562 telephones), 6 dp-gb2a distributors and d.C. Lock release. 34 configure the end of line in the last monitor or telephone. Monitor: dip 6 to on. Telephone: dip 11 to on. Lock release max. 12 vdc/270ma bus bus bus bus bus bus bus d c b a dp- ...

  • Page 35

    Wiring diagrams: 35 video door entry system with 18 vesta7 monitors, 5 dp-gb2a distributors and golmar d.C. Lock release. Configure the end of line in the last monitor. Dip 6 to on. Bus bus bus bus bus bus bus bus d c b a dp- 2 gb a bus bus end of line on end of line off apartment 4 apartment 3 apar...

  • Page 36

    Wiring diagrams: 36 video door entry system with 18 vesta7 monitors, 9 d2l-gb2 distributors and golmar d.C. Lock release. Configure the end of line in the last monitor. Dip 6 to on. Bus bus bus bus d2 d1 d2l- 2 gb bus bus bus bus bus bus d2 d1 d2l- gb2 end of line on apartment 4 apartment 3 remove t...

  • Page 37

    Wiring diagrams: 37 mixed installation: up to 18 elements (vesta7 monitors/nhea hands-free audio terminals), 5 dp-gb2a distributors and d.C. Lock release. Bus bus bus bus bus bus bus bus d c b a dp- 2 gb a end of line on end of line off apartment 3 apartment 2 apartment 1 apartment 17 configuring th...

  • Page 38

    Wiring diagrams: audio door entry system with 32 apartments/t562 gb2 telephones and golmar d.C. Lock release: na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relayé 2 relay 1 _ 12vdc lock release max. 12 vdc/270ma. Ap apartment 1 twisted pair 2x0.75mm 2 twisted pair 2x1mm 2 60m a 60m b 80m 80m cable 10...

  • Page 39

    Wiring diagrams: audio door entry system with 32 apartments/nhea hands-free audio terminals and golmar d.C. Lock release: na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relay 2 relay 1 _ 12vdc lock release max. 12 vdc/270ma. Ap twisted pair 2x0.75mm 2 twisted pair 2x1mm 2 60m a 60m b 80m 80m cable 10m...

  • Page 40

    Wiring diagrams: audio door entry system with 128 apartments/t562 gb2 telephones and golmar d.C. Lock release: (the el632 gb2a sound module should be set to 'operating mode 2' audio only, see page 26). 40 nexa modular gb2 audio and video door entry system - building na2 + ap- c1 na1 ap+ c2 ap+ ap- p...

  • Page 41

    Wiring diagrams: audio door entry system with 128 apartments/nhea hands-free audio terminals and golmar d.C. Lock release: (the el632 gb2a sound module should be set to 'operating mode 2' audio only, see page 26). 41 nexa modular gb2 audio and video door entry system - building na2 + ap- c1 na1 ap+ ...

  • Page 42

    42 bus bus bus bus d c b a dp- 2 gb a end of line off ap ap on 1 2 3 4 5 6 sw1 on 1 2 3 4 5 6 sw1 ap ap on 1 2 3 4 5 6 sw1 on 1 2 3 4 5 6 sw1 (1) (1) (1) (1) video door entry system: to the distributors (building floors) audio door entry system: to the telephones (building floors) lock release max. ...

  • Page 43

    Wiring diagrams: 43 na2 + ap- c1 na1 ap+ c2 ap+ ap- p1 p2 busbus relay 2 relay 1 _ 12vdc ap1 bus relay 2 relay 1 12vdc connection of 2 dc lock releases without “ap”: important: with 2 d.C. Lock releases, it is not possible to use the “ap” door release buttons. (1) to the fa-gb2/a power supply mains ...

  • Page 44

    Golmar@golmar.Es www.Golmar.Es sistemas de comunicación s.A. Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice. Golmar s.A. C/ silici, 13 0894...