end of the exit tube.
• With the BOV in CC mode, Fully inflate the counterlung
• Immerse and look for leaks.
• Repeat for inhale counterlung (there is no LCV cap to cap off).
REGULATOR WIRELESS HP TRANSMITTER TESTING
• Connect a diving cylinder
• Turn on the wrist display and complete the pre-dive sequence
• During the Pre-dive HP gas test sequence, if the first stage transmitter
battery is low, a warning will appear (Fig. 6.7) or if low at the start or end of
a yellow warning (Fig. 6.8) will appear.
DANGER: If you are in doubt as to the HP readings on EXPLOR-
ER, you must check it by attaching a normal gauge and hose to
the HP post.
PUTTING ASSEMBLIES TOGETHER
• Ensure the Canister is in place and secured with it’s 4 screws
• Fit the Sensor Module, EXPLORER Module and Right Hand end cap
along with a new Absorbent Filter.
• Fit the LP hose to the ADV
• Fit the counterlungs and the LCV port cap to the exhale counterlung
• Fit the LP hose to the BOV
• Fit the hoses to the BOV
• Fit the cylinder and the DIN wheel
• Connect the LP hose to the BCD inflator