Home Sentinel VI 450 Owner's Manual - page 14
14
Identifying the Parts
1. Microphone
This highly sensitive microphone will pick up sound within
the effective operating range of the camera
2. Linking Wires
To hook unit up with main monitor unit
3. CCD Camera
Delivers a clear detailed picture to the monitor
4. Microphone Sensitivity Adjust
Turn the knob to adjust the microphone gain to appropriate level
5. Fasten Screws
Comes with 2 screws to fasten the dome camera
Installation
1. If installing the Dome camera in a small enclosed area,
adjust the microphone sensitivity to a lower level.
2. Route the 2 wires from the Dome Camera to the main
monitor unit, terminals DR2/CAM1 or CAM2 or CAM 3.
( Non-polarity )
3. For system set-up press and hold the left button on the
main monitor unit for 2 seconds to enter the set-up mode.
4. In the set-up mode, select by pressing the left and right
buttons to the corresponding physical wiring terminal name,
(e.g. CAM3: ON). Press the middle button to alter the status,
and reset the handset to end system set-up.
5. Any monitor unit connected to this system can monitor
this camera by pressing the Audio/Video monitoring button
Installation and Set-up Procedure for adding another Outdoor Camera CA 455
Door Release Monitor
+ -