IAG ICS6SE3 Installation and operation manual - page 9
ACS6SE2 and ICS6SE3 60cm Cooktop Installation and Operation Manual
- 9 -
Positioning (continued)
This appliance is classified as Class 3 and therefore is to be built into a kitchen unit (depending on size)
or 600 mm worktop, providing the following minimum distances are allowed:
700 mm between the hob surface and the underside of any horizontal surface above it.
650mm distance between cooktop and base of Rangehood filters should be present..
50 mm clearance around the appliance and between the hob surface and any combustible
materials.
Unpacking the appliance
When unpacking the appliance please check that the following items are contained within the
packaging:
1 Electric cooktop
1 Installation and instruction manual
4 Fixing screws
4 Clamps
1 Sealing strip
Installing the appliance
Cut a hole in the worktop that corresponds with the drawing shown below.
Heat shield requirement
IMPORTANT: When installing the cooktop above a drawer or cupboard with access from the
underside a heat shield must be fitted a minimum 25mm below the base of the cooktop as
illustrated below to prevent injury from heat generated from the cooktop. When installed above
an oven this heat shield is not required.