Icare TA01i Instruction Manual

Summary of TA01i

  • Page 1

    Www.Icaretonometer.Com 1 u s er ’ s a n d m a i n t en a n ce m a n u a l english instruction manual.

  • Page 2

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 2 tonometer icare® ta01i instruction manual ta01i-001 en-3.1 the information in this document is subject to change without prior notice. In a conflict situation the english version prevails. 0044 this device complies with: medical device ...

  • Page 3

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 3 indications for use the icare tonometer ta01i is intended to be used for the measurement of intraocular pressure of the human eye. Introduction the icare tonometer is used in the diagnosis, follow up and screening of glaucoma. It is bas...

  • Page 4

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 4 to obtain firm support for the patient’s forehead, in order to obtain an accurate measurement at the right distance, you can adjust the forehead support by turning the forehead support adjusting wheel. Open the probe tube by removing th...

  • Page 5

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 5 probe to the patient’s cornea (see picture) should be 4-8 mm (1/6-1/3 inch). If necessary, adjust the distance by turning the forehead support adjusting wheel. Press the measurement button lightly to perform the measurement, taking care...

  • Page 6

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 6 diagram of tonometer functions technical information type: ta01i. The device conforms to ce regulations. Dimensions: 13 – 32 mm (w) * 45 – 80 mm (h) * 230 mm (l). Weight: 155 g (without batteries), 250 g (4 x aa batteries). Power supply...

  • Page 7

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 7 performance data the performance data is obtained from a clinical study, performed according to american national standard ansi z80.10-2003 and international standard iso 8612.2 for tonometers. The study was performed ain the department...

  • Page 8

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 8 battery compartment cover replacing the probe base replace the probe base every twelve months. Clean or replace the probe base if the error messages e01 or e03 are displayed. Instructions for replacing the probe base: • turn off the ton...

  • Page 9

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 9 returning the icare tonometer for servicing /repair contact icare finland’s technical services department (see www.Icarefinland.Com) or your local icare representative for shipping instructions. Unless otherwise instructed by icare finl...

  • Page 10

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 10 ta01i is class b equipment and needs special precautions regarding emc and needs to be installed and put into service according to emc information provided in user and maintenance manual. Guidance and manufacturer’s declaration-electro...

  • Page 11

    Icare tonometer ta01i manual  english www.Icaretonometer.Com 11 guidance and manufacturer’s declaration – electromagnetic immunity icare ta01i is intended for use in the electromagnetic environment specified below. The customer or the user of the icare ta01i should assure that it is used in such an...