Interface 9834 Instruction Manual - page 16
PROGRAM INSTRUCTIONS (CONT)
17. Depress MODE (S1) switch once.
The text
SP4 HI or SP4 LO
will be displayed. Reference SP1 HI
setup instructions on Page 11 to set SP4 HI or SP4 LO.
18. Depress MODE (S1) switch once.
The text
SEt SP
will be displayed momentarily, followed by the
current value of Setpoint 4. Reference SEt SP setup instructions
above to set a new value for Setpoint 4.
19. Depress MODE (S1) switch once.
The text
HL
will be displayed momentarily, followed by the current
value of Hysteresis Low. Use S2, S3 and/or S4 to set a new value
for HL. To store the new value of HL in non-volatile memory, depress
the MODE switch. To exit the MODE sequence, without storing the new
value, depress the RESET switch.
20. Depress MODE (S1) switch once.
The text
HH
will be displayed momentarily, followed by the current
value of Hysteresis High. Use S2, S3 and/or S4 to set a new value
for HH. To store the new value of HH in non-volatile memory, depress
the MODE switch. To exit the MODE sequence, without storing the
new value, depress the RESET switch.
21. Depress MODE (S1) switch once.
The text
AgAIn
will be displayed. Depress MODE switch one more
time to exit the MODE sequence.
Page 13