Intermec CV60 Installation Manual - page 5
5
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Remote Sense Input (Optional, CV60 only)
Use this input if you want the UPS to send a shutdown signal to the
CV60 Vehicle Mount Computer.
Note: Remove the dust cover from the circular conĆ
nector before installing the cable.
Installation:
1 Cut the 2 pin connector end from the cable (P/N 226-340-001)
and wire the toggle switch as shown.
2 Install the cable into the 4 pin connector.
Operation:
1 Close the switch (ON) to have the CV60 shutdown (after config
uring the UPS service in software.)
2 To remove the shutdown signal to the CV60, move the toggle
switch back to the OFF position.
3 When the battery is low, there are two thresholds that are
reached:
S the UPS will signal the CV60 to shut down via the low
battery line
S the UPS itself will shut down to conserve battery power.
(The LED turns off).
4 The UPS will awaken when external power is applied and the
battery is charged to a minimum level.
Green/White
Red
X
P/N 226-340-001
Switch
Switch Wiring Diagram
Black - No Connection