Jablotron JA-60GSM Installation Manual - page 12
JA-60GSM communicator module
- 12 -
MFJ51212
11 Brief list of programming sequences
Function
Sequence
Options
Factory default
Tel. numbers for SMS and audible
reports
7t xxx..x F0
t = memory from 1 to 8
xxxx = tel. number (max.20 digits), F9=”+”
blank
Event SMS reports
81 uu t y
Event acoustic reports
82 uu t y
uu = events index from 01 to 31
t = memory from 1 to 8
y=0 disabled, y=1 enabled
t=1&2 alarm SMS
t=3&4 alarm SMS + audible
t=5&6 alarm+arming SMS + audible
t=7&8 audible alarm only
SMS and audible reports SW
80 y
y=0 disabled, y=1 enabled, y=2 (enabled with
restrictions)
enabled
GSM signal checking
91 y
y=0 disabled, y=1 enabled
disabled
Incoming call reaction
93 x
x = 0 no reaction
x = 1 to 8 answer after 5 to 40 seconds
x = 9 answer after the 1
st
ring of the 2
nd
call
after 25 seconds
Service remote access code
94 xxxxxxxx F0
xxxxxxxxx = code, it can have form 1 to 8 digits
deleting - 94F0 - remote access is not possible
0000
User remote access code
94 xxxxxxxx F1
xxxxxxxxx = code, it can have from 1 to 8 digits
deleting 94F1 - remote access is not possible
1111
Confirmation SMS reply
95 y
y=0 disabled, y=1 enabled
if disabled, end instruction with C to get the reply
enabled
Reset
96060
Reset to factory default settings
Reset & no reports
96061
Reset to factory default settings & all reports disabled
Immediate codeless dialing-in
970
If entered while in programming, you can dial-in after the 1
st
ring without the access code
Measuring of GSM signal
971
If entered while in programming, it shows GSM signal strength (from 0 to 9)
Volume adjustment of the
connected phone
974x
975x
Level adjustment of received and outgoing signal
(from 1 to 9)
5 – medium level
GSM Module Reset
976
If entered while in programming mode, the GSM module will be disconnected from and
connected to the GSM network.
It is also possible to send the command via SMS in the
form yyyyy*GSM.
Attached phone function
98 y
y=0 telephone line y=2 no function
y=1 alarm keypad y=3 emergency call
telephone line
Emergency call number
99 xxxxxx F0
xxxxxx = tel. number (max.20 digits), F9=”+”
erased
CMS telephone numbers
0y p xxxxx F0
y=1 primary number, y=2 back up number
p=1 CMS1, p=2 CMS2
xxxx = tel. number (max.20 digits), F9=”+”
all erased
Account ID
03 p zzzz F0
p=1 CMS1, p=2 CMS2
zzzz account ID, z=0 to 9 or A=F1, B=F2, C=F3,
D=F4, E=F5 and F=F6
0000 for both CMSs
CMS protocol
04 p x
p=1 CMS1, p=2 CMS2
x=0 CID, x=1 SMS, x=2 GPRS
CID for both CMSs
Events to report
05 p uu y
p=1 CMS1, p=2 CMS2
uu = events index from 01 to 31
y=0 disabled, y=1 enabled
all reports disabled
CMS redialing pause
06 p t
p=1 CMS1, p=2 CMS2
t=1 to 9 (x 5minutes)
5 minutes
Periodic test interval
07 p hh mm
p=1 CMS1, p=2 CMS2
hh mm hours minutes
24hr. after the last report
CMS reports SW
00 p y
p=1 CMS1, p=2 CMS2
y=0 disabled, y=1 enabled
disabled for both CMSs
CMS2 as a backup of CMS1
08 y
y=0 two independent CMS
y=1 CMS2 is a back up for CMS1
two independent CMS
Storing the event “data to CMS
sent” into the event list
09 y
y=0 ... disable , y=1 ... enable
Enable