Jablotron JA-60GSM Installation Manual - page 6
JA-60GSM dialer module
- 6 -
MFJ51212
4.2 SMS text editing
The list of SMS texts stored in the dialer consists of texts reported as
event reports (installation name, event name and source name) and
texts for remote control instructions. All these texts can be changed by
the following SMS form:
yyyyy
∗
TXT
∗
y,text, y,text,…..
where
yyyyy
is the remote access code; default setting is 0000 (4
zeros); the code can be changed, see 5.4
TXT
is the text programming command
y
is the text index (from 1 to 711, see table 4.2.1).
,
comma (separator)
text
is the new customized text string. Neither a comma nor a
period (full stop) can be used inside the text. A space
inside the text is a valid character (the dialer ignores
spaces outside the “text” string)
Note: a single TXT command SMS can change more than one text
(limited by the maximum SMS size of the SMS in of the GSM network).
Example: If the factory default code in the dialer is 0000 (four zeros),
then sending SMS:
0000
∗
TXT
∗
201, uncle Sam’s controller, 202, aunt Mary’s controller
to the dialer will change the names of remote controller numbers 1 and
2.
4.2.1
Table – complete list of SMS texts
Text index y
Factory default text
Text index y
Factory default text
1
Intruder alarm – instant zone
403
Wireless detector #3
2
Intruder alarm – delayed zone
404
Wireless detector #4
3
Fire alarm
405
Wireless detector #5
4
Panic alarm
406
Wireless detector #6
5
Wrong access code alarm
407
Wireless detector #7
6
Alarm after power on
408
Wireless detector #8
7
Tamper alarm
409
Wireless detector #9
8
Tamper OK
410
Wireless detector #10
9
Alarm end
411
Wireless detector #11
10
Alarm canceled by a user
412
Wireless detector #12
11
Arming
413
Wireless detector #13
12
Disarming
414
Wireless detector #14
13
Partial arming (Home)
415
Wireless detector #15
14
No code arming
416
Wireless detector #16
15
External communication failure
501
User code #1
16
External communication recovery
502
User code #2
17
Failure
503
User code #3
18
Failure recovery
504
User code #4
19
AC failure longer than 30 minutes
505
User code #5
20
AC failure
506
User code #6
21
AC recovery
507
User code #7
22
Battery failure
508
User code #8
23
Battery recovery
509
User code #9
24
Enter programming mode
510
User code #10
25
Exit programming mode
511
User code #11
26
Remote access
512
User code #12
27
Remote access – end
513
User code #13
28
RF jamming
514
User code #14
29
Internal communication failure
600
Control panel status:
30
Internal communication recovery
601
Armed
31
Periodic test
602
Disarmed
101
Control panel
603
Exit delay
102
Subsystem
604
Entrance delay
103
Wireless siren
605
Alarm
104
GSM dialer
606
Programming mode
105
Digital line
607
User mode
110
Master code
608
Partially armed
201
Controller #1
609
Battery failure
202
Controller #2
610
Tamper alarm
203
Controller #3
611
Alarm memory
204
Controller #4
612
System failure
205
Controller #5
613
Power supply failure
206
Controller #6
614
Control panel status unknown
207
Controller #7
621
Time:
208
Controller #8
622
Last event:
301
Wired detector #1
623
SMS processing failure.
302
Wired detector #2
624
Credit unknown
303
Wired detector #3
625
Text will be inserted by instruction CREDIT (see 5.14)
304
Wired detector #4
650
SMS processed successfully.
305
Wired detector #5
651
Wrong SMS processing.
306
Wired detector #6
653
AUX switched ON
307
Wired detector #7
654
AUX switched OFF
308
Wired detector #8
700
Alarm system reports:
309
Wired detector #9
703
AM
310
Wired detector #10
704
DM
311
Wired detector #11
705
MO
312
Wired detector #12
706
ME
313
Wired detector #13
707
AUXON
314
Wired detector #14
708
AUXOFF
315
Wired detector #15
709
CREDIT
316
Wired detector #16
710
PGON
401
Wireless detector #1
711
PGOFF
402
Wireless detector #2