Jackson Systems Comfort System T-32-P Installation Manual - Tt Terminal Functions
ADVANCED INSTALLER SETTINGS MENU
Symbol
Default
Function
BD
19.2
Baud Rate
BD=4.8
BD=9.6
BD=19.2
CD
0
Commissioning Mode
CD=0 - OFF
CD=1 - All internal time delays are overridden
This function must be reset to CD=0 to prevent
equipment from short cycling
TS
0
Factory Test
TS=0 - Test Mode OFF
Do not change this function without reading the
Factory Test Mode instructions on Page 27
The ‘T’ and ‘T’ terminals on the T-32-P are used for wiring either an indoor or an outdoor remote
sensor.
Each configuration requires setup in the Advanced Installer menu.
There are two type of remote sensors. The T-32-S1 is a single sensor that can be used indoors or
outdoors. The T-32-S2 contains two sensors. A combination of both sensors can be used for indoor
temperature averaging to simplify wiring.
When the T-32-S1 is used as an outdoor
sensor, the T-32-P will display the
outside air temperature. In the Advanced
Installer menu, TT=OA. The outdoor
sensor can also be used for high and
low balance point control in dual fuel
systems and conventional heat pumps.
Use separate 18-2 thermostat
cable when wiring the sensor to the
thermostat. If the outdoor sensor fails, or
is not wired properly, two dashes will
appear on the LCD where the outside
temperature would normally be
displayed. (Figure 6)
REMOTE SENSORS
OUTDOOR SENSOR WIRING
TT TERMINAL FUNCTIONS
W2
Y2
W1
O/B
Y1
G
R
24
24C
B
A
T
T
T-32-S1 SENSOR
FIGURE 6
11