JALpower D-NS SERIES User Manual - page 12
Model
3600-NS
*
DC input Data
Max. DC power(W)
Max. DC voltage (V)
MPPT voltage range (V)
Starting voltage (V)
Max. DC current (A)
DC overcurrent protection(A)
No. of DC connectors
No. of MPPTs
DC overvoltage category
DC connector
AC Output Data
Norminal AC power(VA)
Max. AC power(VA)
Max. AC current(A)
AC overcurrent protection(A)
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC overvoltage category
Efficiency
Max. efficiency
Euro efficiency
4680
580
80~550
120
22
27.5
2
1
3680
3680
16
24
97.8%
97.5%
5000-NS
6500
580
80~550
120
22
27.5
2
1
22.8
35
5000*
5000*
**
50/60Hz; 220/230Vac
45~55Hz/55~65Hz; 180~270Vac
0.8 leading~0.8 lagging
Single phase
Category
Ⅲ
4200-NS
5460
580
80~550
120
22
27.5
2
1
4200
4200
19
29
97.8%
97
.
5%
97.8%
97
.
5%
Category
Ⅱ
AMPHENOL/MC4/SUNCLIX
MPPT adaptation efficiency
99.9%
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch
AC over current protection
Insulation monitoring
Certifications&Standards
Grid regulation
Safety
EMC
Integrated
Integrated
Integrated
(optional)
Integrated
Integrated
VDE-AR-N 4105, AS4777.2&.3, RD1699, IEC62109-2/1, VDE0126-1-1+A1, EN50438 G83/G59
IEC62109-1&-2, AS3100
EN 61000-6-1,EN 61000-6-2,EN 61000-6-3,EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
19
20
Model
1000-NS
1500-NS
3000-NS
2000-NS
2500-NS
Protection
Residual current monitoring unit
Anti-islanding protection
DC switch
AC over current protection
Insulation monitoring
Certifications&Standards
Grid regulation
Safety
EMC
General Data
Dimensions (WxHxD)
Weight (kg)
Mounting
Ambient temperature range
Relative humidity
Moisture location category
Max. operating altitude
Protection degree
Environment category
External environment pollution degree
Topology
Night power consumption(W)
Cooling
Noise emision(dB)
Display
Communication
Standard warranty(years)
Integrated
Integrated
Integrated
(optional)
Integrated
Integrated
G83/2, AS4777.2&.3,
VDE0126-1-1, En50438, ERDF-NOI-RES_13E;
According to IEC62109-1&-2,
AS3100
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3
344*274.5*128mm
Wall bracket
-25~60°C
(>45°C derating)
0~95%
4K4H
4000m(>2000m derating)
IP65
Outdoor & indoor
Grade1
、
2
、
3
Transformerless
Nature convection
LCD
USB2.0;
Wi-Fi
or
RS-485
5/10/15/20/25
(optional)
7.5
8.5
96.2%
>
96
.
0%
96.2%
>
96
.
0%
15
50/60Hz; 220/230Vac
45~55Hz/55~65Hz; 180~270Vac
0.8 leading~0.8 lagging
Single phase
Category
Ⅲ
>
99.9%
97.2%
>
97
.
0%
97.2%
>
97
.
0%
AC overcurrent protection(A)
Norminal AC output
AC output range
THDi
Power factor
Grid connection
AC overvoltage category
Efficiency
Max. efficiency
Euro efficiency
MPPT adaptation efficiency
96.2%
96.0%
**
3200 for Thailand PEA, 3000 for other countries.
*
4600 VDE-AR-N4105;4950 fro Australian;5000 for other country.
7
11
19
20
**
22.8 for other country;21.7 fro Australian.
5K-NS
6500
580
80~550
120
22
27.5
2
1
21.7
35
4600
4950