JALpower D-NS SERIES User Manual - page 8
●
Pay attention to the direction of CT when wiring. CT clip should be locked tight. White cable should connect Line 6 and black cable
should connect Line 5. Tighten them with screwdriver. Make sure CT cables connected to the right output phase lines of inverter
when in use.
●
Without connection of CT, inverter will show “CT Disconnect”. If CT is connected reversely, inverter will show “CT Reverse”when
it enters into on-grid status .
2. Connection Procedure:
●
Put the cable through the components in this order: screw cap, one-hole sealing ring, insulation body and sheet metal parts.
●
Take the green terminal out of accessory bag. cable should be connected as Figure
3.4.7-1.
●
Insert the green terminal into the corresponding interior terminal of the inverter. Pull cable softly to maintain the cable not to be
pulled out.
●
Lock the sheet metal parts onto the box and tighten the screw cap.
Line
1
2
3
4
5
6
Function
Figure
3
.
4
.
7
-
2
123456
CT
+
CT
-
Digital
output
Digital
output
Reserved
Reserved
11
12
3.4.6 Wi-Fi Communication
The Wi-Fi communication function is only applied to WiFi box, the detailed configuration instruction can be referred to Wi-Fi
Configuration in the accessory box.
Connection Procedure:
●
Take out the interior cable of the inverter.
●
Insert cable into the WiFi BOX.
please
refer
to
Figure
3
.
4
.
6
-
1
.
●
Lock the
BOX onto the chassis tightly.
WiFi
Figure
3
.
4
.
6
-
1
3
.
4
.
7 Power Limiting device installation
Connection method of
CT please refer to Figure 3.4.7-1.
Power Limiting device
Router
Inverter
N
Switch Board
L
CT
1-White wire
2-Black
wire
Figure
3
.
4
.
7
-
1
NOTE
:
After installation is completed, please set up power limiting function referring to section 4.5
POWER
RUN
FAULT