Kaba Mas 1F Operating Instructions Manual - Supervisory/subordinate Mode
10
Note: If at any time the dial remains stationary for more than 40 seconds,
the computer will reset (LCD will go blank) requiring the operator to redial the
entire combination.
SUPERVISORY/SUBORDINATE MODE
In this mode, two combinations must be correctly dialed to open the lock. However, it is
different from Dual Mode because the Supervisory Combination
must only be dialed once to UnLock (UL) the lock. Once the
Supervisory Combination has been entered, the Subordinate
Combination can be used to open the lock at any time during this
“unlocked” state.
Whenever the Supervisory Combination is redialed, the lock will
display LU (Locked Up), and the Subordinate Combination will no
longer open the lock.
To UnLock (UL)
Supervisory Operator:
1. Dial left (CCW) until lock is “powered”.
2. Dial the Supervisory Combination as if dialing a combination to open the lock; i.e.,
left (CCW) to dial the fi rst number, right (CW) to dial the second number, left (CCW)
to dial the third number.
EXAMPLE: Combination = 25-50-75
Dial left to fi rst number, 25. Stop.
Dial right to second number, 50. Stop.
Dial left to third number, 75. Stop.
3. Dial
right (CW). UL (UnLocked) is displayed indicating that the Subordinate Operator
can now open the lock using only the Subordinate Combination. The X-09 will now
operate as if it were in a single combination mode.
To Open the Lock
Subordinate Operator:
1. Dial left (CCW) until lock is “powered”.
2. Dial the Subordinate Combination in the correct manner to open the lock; i.e., left
(CCW) to dial the fi rst number, right (CW) to dial the second number, left (CCW) to
dial the third number.
EXAMPLE: Combination = 30-60-90
Dial left to the fi rst number, 30. Stop.
Dial right to second number, 60. Stop.
Dial left to third number, 90. Stop.
3. Dial
right (CW). After OP with a right arrow (OPen right) is displayed, continue dialing
to the right to retract the lock bolt.
Note: If at any time the dial remains stationary for more than 40 seconds,
the lock will reset (LCD will go blank) requiring the operator to redial the
entire combination.