KanexPro MX-HDBASE4x4-4k User Manual - Kanexpro
KANEXPRO
MX-HDBASE4x4-4k
24 |
P a g e
Command
Function
Feedback Example
5. 3840x2160 2D (30Hz)
When the switcher gets the command, it
will show a message to send EDID file
(.bin file). Operations will be invalid after
10 seconds.
GetIntEDID[x].
Return the embedded EDID data ranked
x, [x]=1~5
GetInPortEDI
D[X].
Return the EDID data of input [x], [x]=1~4
%0801.
Auto HDCP management, activate carrier
native mode
%0801
%0900.
Switch to carrier native mode.
Carrier native
%0901.
Switch to force carrier mode.
Force carrier
%0911.
Reset to factory default.
Factory Default
%9951.
Check the command sent by port 1 when
PWON.
Port
1:data
when
PWON
%9952.
Check the command sent by port 2 when
PWON.
Port
2:data
when
PWON
%9953.
Check the command sent by port 3 when
PWON.
Port
3:data
when
PWON
%9954.
Check the command sent by port 4 when
PWON.
Port
4:data
when
PWON
%9955.
Check the command sent by port 1 when
PWOFF.
Port
1:data
when
PWOFF
%9956.
Check the command sent by port 2 when
PWOFF.
Port
2:data
when
PWOFF
%9957.
Check the command sent by port 3 when
PWOFF.
Port
3:data
when
PWOFF
%9958.
Check the command sent by port 4 when
PWOFF.
Port
4:data
when
PWOFF
%9961.
Check the system locking status.
System
Locked/
Unlock!
%9962.
Check the power status
STANDBY/PWOFF/
PWON
%9963.
Check the working mode of infrared
carrier.
Carrier native/ Force
carrier