Www.Karcher.Com 5.959 - 657 (04/00) hds 698 c.
Hds 698 c 1 2 3 4 5 6 7 8 9 10 11 12.
Hds 698 c 13 14 15 16 17 18 19 20
Hds 698 c operating instructions 5 spare parts list 13.
English hds 698 c 5 contents environmental protection 5 overview 6 commissioning 6 check the oil level 6 filling with scale inhibitor 6 filling with fuel 6 filling with cleaning agent 6 mounting handgun 6 water connection 7 drawing in water from tank 7 mains connection 7 operation 7 switching on uni...
English hds 698 c 6 overview fig. 1 1 swivel caster with parking brake 2 connection for high-pressure hose 3 fuel tank inlet 4 high-pressure hose 5 cover latch 6 handgun 7 pressure gauge 8 filler opening for cleaning agent and metering equipment 9 water connection "1" with strainer fig. 2 1 selector...
English hds 698 c 7 water connection for connected loads, refer to technical data. Mount supply hose at water connection of unit. Fig. 1 item 9 (supply hose is not part of scope of delivery) drawing in water from tank the following conversion work is necessary if water is to be drawn in from an exte...
English hds 698 c 8 fig. 10 set cleaning-agent concentration as specified by manufacturer 0 =working without cleaning agent metering setting concentration 1 0,25% 2 1,00% 3 1,25% 4 1,50% 5 1,75% 6 2,00% approximate values at maximum operating pressure intended use cleaning of: machines, vehicles, bu...
English hds 698 c 9 each time after usage following operation with cleaning agent – set cleaning-agent regulator to "0" – set mode selector switch to "i" – actuate handgun and flush unit for approx. 1 min stopping machine – set mode selector switch to "0" – shut off water supply – briefly (approx. 5...
English hds 698 c 10 maintenance tasks cleaning strainer in water connection fig. 15 – remove strainer – clean in water and re-insert cleaning strainer in low water protection fig. 16 – unfasten union nut and detach hose fig. 17 – take out strainer if necessary, screw in bolt m8 approx. 5mm to pull ...
English hds 698 c 11 burner not ignited fuel tank empty – fill up lack of water – check water connection, check supply lines, clean low water protection. Fuel filter dirty – replace fuel filter. Incorrect direction of rotation. If direction of rotation is correct, powerful jet of air will be felt at...
English hds 698 c 12 technical data mains connection 200 v 3~50 hz connected power 3,6 kw fuse protection (slow response) 16 a mains connection 200 v 3~60 hz connected power 3,6 kw fuse protection (slow response) 16 a water connection supply temperature max. 30 c supply quantity min. 900 l/h suction...
Hds 698 c 13.