Kauoheng KH-313 SERIES Operation Manual - 6. Cam Plate Distance
6. Cam plate distance
The distance between cam plate and needle bed is maximum 0.15 ㎜,
Fig.6.1 shows how to check and adjust.Please check it by every 3
months, loosen the stepped screw and turn the bearing pin to adjust the
Stepped screw
Bearing pin
distance, make sure to tighen the stepped screw after adjustment.
0.10~0.15mm
Fig.6.1 Adjust cam plate distance
7. Remove carriage
When it becomes necessary to remove the carriage, it can be remove
from the left hand side or the right hand side. The procedures are as
following:
○
1
Turn off the power firstly.
○
2
Remove the side cover
.
○
3
Disconnect the two plugs on back of carriage.
○
4
Remove the fitting screw and cap bolt on connecting plates as
shown in Fig.7.1.Then pay attention to remove the carriage.
○
5
After replacing the carriage, it must be confirmed that the plugs,
fitting screws and cap bolts are all completely connected, then start
machine.
Plug
Fitting screw
Cap bolt
Fig.7.1 Remove the carriage