Maintenance and cleaning
Regular maintenance is required for the safe opera-
tion of the towers and has to be documented. Clean-
ing is to be performed when necessary.
DANGER
Live parts
Risk of fatal injury due to electric shock
when touching live parts.
• Disconnect from mains and secure
against reconnection!
• USE ONLY ORIGINAL SPARE PARTS.
• Replace illuminants and filters only with ones
wich are characterized on the device.
Instructions for cleaning and
care
GENERAL
Before starting to clean the unit, take off any rings,
bracelets, watches, etc. that you might be wearing in
order to avoid scratching the surfaces.
Cleaning fluid must not run into the appliance.
TUBES
To preserve the tanning power, we recommend
cleaning the tubes and UV lamps with warm water
and a chamois after approx. 200 hours of operation.
ACRYLIC PANES
For cleaning the acrylic panes, use the special
cleansing agent and disinfectant “megaClean“ sup-
plied by KBL and dilute it in water at a ratio of 1:13.
VARNISHED AND PLASTIC PARTS
To clean the varnished and plastic surfaces, use a
damp soapy cloth.
Do not clean the big plastic parts with a dry cloth.
This might scratch the surfaces!
To clean the mirror plate of the floor, proceed as follows:
Use a damp chamois and spray megaClean onto
it sparingly. Then wipe the surfaces clean. NEVER
CLEAN WITH A DRY CLOTH!
Prevent the corners and edges from getting wet.
CLEANING AGENTS
The surfaces and the acrylic panes must not be
cleaned with concentrated disinfectants or sol-
vents or other liquids that contain alcohol!
Maintenance intervals
Component/
wearing part
Cleaning
Replacement
Tubes and
starters
Tubes after
approx. 200
operating
hours
After 500 operating
hours
Acrylic panes
When
necessary
When necessary
aquaCool
nozzles
When
necessary
After approx. 1000
operating hours
Colour filters
of unit light-
ing
When
necessary
Whenever UV
tubes are replaced