Parameter description
Value Function
0
No function (generally off)
1
Generally on
2
Run signal; also by DC-braking
3
Ready signal (no error)
4
Fault relay
5
Fault relay (not at under voltage error)
6
Warning or error message at abnormal stopping
7
Overload alert signal
8
Overtemperature alert signal power modules
9
External overtemperature alert signal motor
10
Only application mode
11
Overtemperature alert signal interior OHI
12…19 Only application mode
20
Actual value = set value (CP.3 = Fcon; rcon; not at noP, LS, error, SSF)
21
Accelerate (CP.3 = FAcc, rAcc, LAS)
22
Decelerate (CP.3 = FdEc, rdEc, LdS)
23
Real direction of rotation = set direction of rotation
24
Utilization > switching level
1)
25
Active current > switching level
1)
26
Only application mode
27
Real value (CP.1) > switching level
1)
28
Setpoint (CP.2) > switching level
1)
29…30 Only application mode
31
Absolute setpoint at AN1 > switching level
1)
32
Absolute setpoint at AN2 > switching level
1)
33
Only application mode
34
Setpoint at AN1 > switching level
1)
35
Setpoint at AN2 > switching level
1)
36…39 Only application mode
40
Hardware current limit activated
41
Modulation on-signal
42…46 Only application mode
47
Ramp output value > switching level
1)
48
Apparent current (CP.4) > switching level
1)
49
Forward running (not at nOP, LS, abnormal stopping or error)
50
Reverse running (not at nOP, LS, abnormal stopping or error)
51
Warning E.OL2
52
Current regulator limit reached
53
Speed regulator limit reached
54…62 Only application mode
63
Absolute value ANOUT1 > switching level
1)
64
Absolute value ANOUT2 > switching level
1)
65
ANOUT1 > switching level
1)
66
ANOUT2 > switching level
1)
67…69 Only application mode
70
Driving current active (safety relay)
71…72 Only application mode
73
Absolut active power > switching level
1)
74
Active power > switching level
1)
75…79 Only application mode
80
Active current > switching level
1)
further on next side