KEDDY SK1000 Installation Instructions Manual

Other manuals for SK1000: Instalation Instructions

Summary of SK1000

  • Page 1

    Fireplace inserts installation instructions model sk1000, sk2000

  • Page 2: Contents

    Contents contents.............................................................................................................................2 general information.....................................................................................................3 important points.....................

  • Page 3: General

    General * pre-heated combustion air * installation kit * steel pipe * outdoor air unit important! Save these installation instructions and the associated firing instructions! Quality approval - ments for the nordic ecolabel. Manufacturer's declaration important points * note! Read through all of the...

  • Page 4: Preconditions

    Preconditions building notice committee in your municipality for up-to-date infor- mation. Flue inserts are also approved for connection to older be connected to chimneys made of prefabricated ele- - - should be at least 3.5 m tall and have an area of ap- prox. 120 cm2. Combustion air supply - the h...

  • Page 5: Surround Installation

    - 5 - surround installation - - tive 2. Preparations frame. Sk1000: b 548 h 500 sk2000: b 648 h 565.

  • Page 6: Installation Guide Alt. 1

    Steelbrush. Measure the distance from the connection hole in - - - apply the combustion air pipe to the steel pipes with sealent. Installation guide alt. 1 - 6 -.

  • Page 7

    4. It is now time to assemble the insert. Remove the box and the bottom plate from the front-door, open the door/doors max and unscrew the four bolts (see ill). Carefully pull the front towards you. (app weight of front and door mod 2001, 35 kg) 5. Put the insert in place (so that it touches the smo...

  • Page 8: Installation Guide Alt. 2

    - 8 - installation guide alt. 2 1. Make a hole in the existing lintel in such a way that you can insert the pipe and insulation. (approximately 300 x 300 mm) 2. Fix the smoke outlet pipe to the insert and adjust the insert to be level with the adjustable feet. Where you want to insulate it against t...

  • Page 9: Care & Firing Instructions

    Care & firing instructions keddy's fireplace inserts have been tested by an approved testing and research institute. They have extremely good environmental values and a useful efficiency of 80%. For the fireplace insert to work optimally, it is of key importance that you follow the care and firing i...

  • Page 10

    Lighting a fire (if the chimney is cold or if there are unfavour- able weather conditions, you may need to keep the door ajar during the first five minutes in or- der to establish a satisfactory chimney draught.) - note! The reason why we want to achieve the optimum operating temperature in the inse...

  • Page 11: Technical Specifications

    - 11 - technical specifications height 470-475 mm width 500 mm depth 400 mm weight 100 kg flue pipe diameter 125 mm output 4-9 kw height 535-540 mm width 600 mm depth 500 mm weight 125 kg flue pipe diameter 125 mm output 5-10 kw.

  • Page 12

    Rev . 1, 01/09/2013.